The fan goes off 30 seconds after the compressor goes
off.
1-4 Automatic operation
The operating mode and temperature setting are
determined by the room temperature and the external
air temperature.
*During Cooling / Dry
1-7 Swing louvre
The louvre is moved by a stepping motor to perform
swing and fixing in the set position.
If the "FLOW DIRECTION" button is prossed during
swing, it will stop. If the "FLOW DIRECTION" button is
prossed while it is stopped, it will swing.
1-8 Restart control
Once the compressor stops, this control prevents it from
starting again for 3 minutes. It also prevents starting for
80 seconds immediately following plugging into the
power outlet.
1-5 ON-timer
The ON-timer is set by pressing the ON-timer button. In
order to attain the set temperature at the set time, the
operation starting time is corrected by neuro and fuzzy
computing one hour before the set time.
1-6 OFF-timer
The OFF-timer is set by pressing the OFF-timer button.
Operation is as follows:
*During Heating
1-3 Hot keep
If the room temperature is in the j or k zone during
heating, the compressor is turned on and off to prevent
overheating.
12
11
10
9
8
7
6
5
4
3
2
1
0
1
2
3
4
e, f zone
g zone
h zone
i zone
Dry
Operating frequency code
Fan speed
12
11
10
9
8
7
6
5
4
3
2
1
0
High
Circulation
Operating frequency code
Fan speed
Med
Low
Heating
(24˚C)
Heating
(23˚C)
Heating
(22˚C)
Cooling
(25˚C)
(Room temperature
- 2°C)
Cooling
(26˚C)
Cooling
(27˚C)
Dry
Room
temperature
(˚C)
21
26
0
10
18
31
34
External air
temperature (°C)
The external air temperature is determined by
detecting the temperature of the outdoor heat
exchanger.
3°C
Room
temperature
Timer set time
1
hour
Timer operation starts
Stops
1°C
Stops
Timer set time
1
hour
Timer operation starts
Room
temperature
Zone Compressor intermittent time
Fan
After "3 min. on - 3 min.off"
is repeated 4 times, the
compressor goes off, and
only the fan continues to
repeat “3 min. on - 8
min.off”.
J
K
3 min. on - 3 min. off
3 min. on - 8 min. off
Same as Compressor
Cooling
Heating
Set temperature
By fuzzy computing
Set the shift up time
Cooling s 1°C
Heating setting - 3°C
Final
Dry
Same as above
(Final s 1°C)