-29-
Model of Outdoor Unit
AE-X18LCJ
Compressor Manufacturer/trademark
SANYO
Compressor Model
C-6RVN93H0N
Compressor Type
twin rotary
L.R.A. (A)
41
Compressor RLA(A)
7
Compressor Power Input(W)
1610
Overload Protector
1NT11L-3979
Throttling Method
Capillary
Starting Method
Capacitor
Working Temp Range (
℃
)
-7
℃≤
T
≤
43
℃
Condenser
Aluminum fin-copper tube
Pipe Diameter (mm)
7
Rows-Fin Gap(mm)
2-1.4
Coil length (l) x height (H) x coil width (L)
806×660×22
Fan Motor Speed (rpm) (H/M/L)
780/600
Output of Fan Motor (W)
60W
Fan Motor RLA(A)
0.26
Fan Motor Capacitor (uF)
3
Air Flow Volume of Outdoor Unit
(m
3
/h)
2700
Fan Type-Piece
Axial fan –1
Fan Diameter (mm)
460
Defrosting Method
Auto defrost
Climate Type
T1
Isolation
I
Moisture Protection
IP24
Permissible Excessive Operating Pressure for the Discharge
Side(MPa)
3.8
Permissible Excessive Operating Pressure for the Suction
Side(MPa)
1.2
Sound Pressure Level dB (A) (H/M/L)
56/54/52
Sound Power Level dB (A) (H/M/L)
66/64/62
Dimension (W/H/D) ( mm)
846X300X685
Dimension of Package (L/W/H)( mm)
994X428X750
Net Weight /Gross Weight (kg)
52/57
Outdoor
unit
Refrigerant Gas & Charge (kg)
R410A /1.60