9
36R-S60
Vertical-Size and Linearity Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "S09".
3. While observing the top and bottom of the screen,
adjust "S09" data value to proper vertical size.
4. Using the R502 control adjust for the best linearity.
Vertical Phase Adjustment
1. Enter the service mode and select the service
adjustment "S06".
2. Adjust data value to "00".
Note: This must be set "00" when changed data
retrace line will appear.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "S07".
3. Adjust "S07" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "S18".
3. A black text box appears on the screen. (see
Figure
B. below)
4. Adjust "S18" data value so that text box is positioned
in the center of the screen.
3.58MHz Trap Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "S16".
3. This is a two position adjustment, "00" is ON, "01" is
OFF.
4. Adjust data value to "01" for normal viewing.
Sharpness and Audio Balance Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustments "S05" for sharpness and "S17" for audio
balance.
»
Sharpness Adjustment
3. Adjust data value to "24"(center of data range) for
sharpness adjustment.
»
Audio Balance Adjustment
4. Adjust data value to "20"(center of data range) for
Audio balance adjustment.
Vertical Center Adjustment
1. Receive a good CATV channel.
2. Adjust the S502 so that the picture is centered.
Side Pincushion Adjustment
1. Receive a good CATV channel or crosshatch pattern
signal.
2. Adjust the R676 so that the outermost line on the
screen is straight.
Horizontal Size Adjustment
1. Receive a good CATV channel or crosshatch pattern
signal.
2. Adjust the R678 so that the best horizontal size.
Energy Save Offset Adjustment
1. Enter the service mode and select the service
adjustment "S20".
2. Adjust data value to "23".
Note : This position is used to preset the level for the
energy save function.
Other Adjustments
1. Enter the service mode.
2. Adjust the following data values as listed below.
Figure B.
SERVICE
ADJUST
DATA
POSITION
ITEM
(Hex)
S05
SHARPNESS
24
S06
V-PHASE
00
S16
TRAP
01
S20
E-SAVE
23
S21
TIMER
7A
S22
FAO
25
S23
TUNER SETUP
00
S28
COL. TEMP. LOW-G
E1
S29
COL. TEMP. LOW-B
AE
S30
COL. TEMP. ML-G
FA
S31
COL. TEMP. ML-B
E7
S32
COL. TEMP. ML-B
08
S33
COL. TEMP. HIGH-G
14
SERVICE
ADJUST
DATA
POSITION
ITEM
(Hex)
OP1
OPTION1
B1
OP2
OPTION2
C7
Summary of Contents for 36R-S60
Page 11: ...11 6 5 4 3 2 1 A B C D E F G H 36R S60 CHASSIS LAYOUT ...
Page 12: ...12 6 5 4 3 2 1 A B C D E F G H 36R S60 BLOCK DIAGRAM ...
Page 14: ...15 36R S60 14 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 1 Unit ...
Page 15: ...17 36R S60 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 2 Unit ...
Page 16: ...18 6 5 4 3 2 1 A B C D E F G H 36R S60 SCHEMATIC DIAGRAM CRT Unit ...
Page 17: ...19 6 5 4 3 2 1 A B C D E F G H 36R S60 SCHEMATIC DIAGRAM CONTROL Unit ...
Page 19: ...21 6 5 4 3 2 1 A B C D E F G H 36R S60 PWB A MAIN Unit Chip Parts Side ...