5
36R-S60
CIRCUIT PROTECTION
The receiver is protected by a 5.0A fuse (F701),
mounted on PWB-A, wired into one side of the AC
line input.
X-RADIATION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal
deflection system, high voltage system, B+ system,
test the X-Radiation protection circuit to ascertain
proper operation as follows:
1. Apply 120V AC using a variac transformer for
accurate input voltage.
2. Allow for warm up and adjust all customer controls
for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to TP653 and make sure
that the voltmeter reads 13.2 ± 0.7V.
5. Apply external 16.2V DC at TP653 by using an
external DC supply, TV must be shut off.
6. To reset the protector, unplug the AC cord and plug
the AC cord power on. Now make sure that normal
picture appears on the screen.
7. If the operation of the horizontal oscillator does not
stop in step 5, the circuit must be repaired before the
set is returned to the customer.
HIGH VOLTAGE CHECK
High voltage is not adjustable but must be checked
to verify that the receiver is operating within safe
and efficient design limitations as specified checks
should be as follows:
1. Connect an accurate high voltage meter between
ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 120V AC
line voltage, with a strong air signal or a properly tuned
in test signal.
3. Enter the service mode and select the service
adjustment "S19" and Bus data "01" (Y-mute on).
4. The voltage should be approximately 33.4kV (at zero
beam).
If a correct reading cannot be obtained, check circuitry
for malfunctioning components. After the voltage test,
make Y-mute off to the normal mode.
INSTALLATION AND SERVICE INSTRUCTIONS
Note:
(1) When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2) Before performing adjustments, the TV set must be on at least 15 minutes.
Summary of Contents for 36R-S60
Page 11: ...11 6 5 4 3 2 1 A B C D E F G H 36R S60 CHASSIS LAYOUT ...
Page 12: ...12 6 5 4 3 2 1 A B C D E F G H 36R S60 BLOCK DIAGRAM ...
Page 14: ...15 36R S60 14 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 1 Unit ...
Page 15: ...17 36R S60 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 2 Unit ...
Page 16: ...18 6 5 4 3 2 1 A B C D E F G H 36R S60 SCHEMATIC DIAGRAM CRT Unit ...
Page 17: ...19 6 5 4 3 2 1 A B C D E F G H 36R S60 SCHEMATIC DIAGRAM CONTROL Unit ...
Page 19: ...21 6 5 4 3 2 1 A B C D E F G H 36R S60 PWB A MAIN Unit Chip Parts Side ...