IMPORTANT SERVICE SAFETY PRECAUTION
(Continued)
BEFORE RETURNING THE RECEIVER
(Fire & Shock Hazard)
Before returning the receiver to the user, perform
the following safety checks.
1. Inspect all lead dress to make certain that leads are
not pinched or that hardware is not lodged between
the chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non-metallic
control knobs, insulating materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacity networks, mechanical
insulators, etc.
3. To be sure that no shock hazard exists, check for
leakage current in the following manner.
•
Plug the AC cord directly into a 120 volt AC outlet,
(Do not use an isolation transformer for this test).
•
Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15
µ
F capacitor in series with
all exposed metal cabinet parts and a known earth
ground, such as electrical conduit or electrical ground
connected to earth ground.
•
Use an AC voltmeter having with 5000 ohm per volt,
or higher, sensitivity to measure the AC voltage drop
across the resistor.
•
Connect the resistor connection to all exposed metal
parts having a return to the chassis (antenna, metal
cabinet, screw heads, knobs and control shafts,
escutcheon, etc.) and measure the AC voltage drop
across the resistor.
AII checks must be repeated with the AC line cord
plug connection reversed. (If necessary, a non-
polarized adapter plug must be used only for the
purpose of completing these check.)
Any current measured must not exceed 0.5 milliamp.
Any measurements not within the limits outlined
above indicate of a potential shock hazard and
corrective action must be taken before returning the
instrument to the customer.
1.5k ohm
10W
0.15
µ
F
TEST PROBE
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
SAFETY NOTICE
Many electrical and mechanical parts in television
receivers have special safety-related characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical
components having such features are identified by "
å
"
and shaded areas in the Replacement Parts Lists and
Schematic Diagrams.
For continued protection, replacement parts must be
identical to those used in the original circuit. The use of
substitute replacement parts which do not have the same
safety characteristics as the factory recommended
replacement parts shown in this service manual, may
create shock, fire, X-radiation or other hazards.
Summary of Contents for 32U-S600
Page 14: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 14 MODEL 32U S600 CHASSIS LAYOUT ...
Page 15: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 15 MODEL 32U S710 CHASSIS LAYOUT ...
Page 16: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 16 MODEL 32U S600 BLOCK DIAGRAM ...
Page 17: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 17 MODEL 32U S710 BLOCK DIAGRAM ...
Page 21: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 21 ...
Page 23: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 23 ...
Page 25: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 25 ...
Page 27: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 27 ...
Page 28: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 28 MODEL 32U S600 SCHEMATIC DIAGRAM CRT Unit ...
Page 29: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 29 MODEL 32U S710 SCHEMATIC DIAGRAM CRT Unit ...
Page 31: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 31 ...
Page 33: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 33 ...
Page 34: ...32U S600 32U S710 8 7 10 9 6 5 4 3 2 1 A B C D E F G H 34 SCHEMATIC DIAGRAM P IN P Unit ...
Page 35: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 35 ...
Page 39: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 39 PWB A MAIN Unit Chip Parts Side ...