32U-S600
32U-S710
12
Ë
MTS ADJUSTMENT
MTS Level Adjustment (32U-S600)
1. Receive the following composite signal.
Monaural signal: 400Hz, 100% modulation
2. Connect the rms voltmeter to pin (39) of IC3001.
3. Enter the service mode and select the service
adjustment "M01" and set to "09".
4. Enter the service mode and select the service
adjustment "EX4".
5. Adjust the data so that the rms voltmeter reads 490
±10 mVrms.
MTS Level Adjustment (32U-S710)
1. Receive the following composite signal.
Monaural signal: 400Hz, 100% modulation
2. Set the sound volume above 1.
3. Connect the rms voltmeter to pin (39) of IC3001.
4. Enter the service mode and select the service
adjustment "M01" and set to "09".
5. Enter the service mode and select the service
adjustment "EX4".
6. Adjust the data so that rms voltmeter reads
490±10mVrms.
7. For 2nd Tuner, adjust the "M06" until the voltage of
pin (36) of IC3001 becomes 490±10mVrms.
MTS VCO Adjustment
1. Keep the unit in no-signal state.
2. Connect the frequency counter to pin (39) of IC3001.
3. Connect a capacitor (100µF, 50V) in between
po) side of C3005 and ground.
4. Enter the service mode and select the service
adjustment "M02"
5. Adjust the data so that the frequency counter reads
62.94 ±0.75kHz.
Filter Adjustment
1. Feed the following stereo pilot signal to pin (14) of
IC3001 .
Stereo pilot signal: 9.4kHz, 600mVrms.
2. Enter the service mode and select the service
adjustment "M03".
3. Adjust the data until "OK" appears in position on the
screen. Make sure the "OK" is displayed almost at
the center of the data range.
Separation Adjustment (32U-S600)
1. Input "SIGNAL 1" (TU51) and vary the "M04" bus data
to get the minimun AC voltage to pin (39) of IC3001.
2. Input "SIGNAL 2" (TU51) and vary the "M05" bus data
to get the minimun AC voltage to pin (39) of IC3001.
SIGNAL 1: 300Hz, 30% modulation, Lch only, NR-ON
SIGNAL 2: 3kHz, 30% modulation, Lch only, NR-ON
Check the output of the speaker at the maximum
volume as stated below.
Confirmation spec:
ADJ spec: above 25 dB
CHK spec: above 20 dB
Separation Adjustment (32U-S710)
1. Input "SIGNAL 1" (TU51and TU52) and vary the
"M04" and "M07" bus data to get the minimun AC
voltage to pin (39) of IC3001.
2. Input "SIGNAL 2" (TU51and TU52) and vary the
"M05" and "M08" bus data to get the minimun AC
voltage to pin (39) of IC3001.
SIGNAL 1: 300Hz, 30% modulation, Lch only, NR-ON
SIGNAL 2: 3kHz, 30% modulation, Lch only, NR-ON
Check the output of the speaker at the maximum
volume as stated below.
Confirmation spec:
ADJ spec: above 25 dB
CHK spec: above 20 dB
Summary of Contents for 32U-S600
Page 14: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 14 MODEL 32U S600 CHASSIS LAYOUT ...
Page 15: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 15 MODEL 32U S710 CHASSIS LAYOUT ...
Page 16: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 16 MODEL 32U S600 BLOCK DIAGRAM ...
Page 17: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 17 MODEL 32U S710 BLOCK DIAGRAM ...
Page 21: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 21 ...
Page 23: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 23 ...
Page 25: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 25 ...
Page 27: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 27 ...
Page 28: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 28 MODEL 32U S600 SCHEMATIC DIAGRAM CRT Unit ...
Page 29: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 29 MODEL 32U S710 SCHEMATIC DIAGRAM CRT Unit ...
Page 31: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 31 ...
Page 33: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 33 ...
Page 34: ...32U S600 32U S710 8 7 10 9 6 5 4 3 2 1 A B C D E F G H 34 SCHEMATIC DIAGRAM P IN P Unit ...
Page 35: ...32U S600 32U S710 17 16 19 18 15 14 13 12 11 10 35 ...
Page 39: ...32U S600 32U S710 6 5 4 3 2 1 A B C D E F G H 39 PWB A MAIN Unit Chip Parts Side ...