Focus Adjustment
1. Receive a good local channel.
2. Adjust the VR-1 (upper knob) and VR-2 (middle knob)
of the flyback transformer to make the image as fine
as possible.
C. C Display Position Adjustment
1. Receive the lion head pattern signal.
2. Select "EX2" to display the text box.
3. Adjust the "EX2" bus data to let the text box displayed
in the center.
Vertical-Size and Linearity Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D03" for V-size.
3. Adjust the "D03" bus data to get the proper V-size.
4. For V-linearity adjustment, select data bus "D05" and
adjust to get the proper vertical linearity.
Note: Aging for 10 min before adjustment. After the
adjustment of V-center and V-size, re-
adjustment for this V-line.
Vertical Phase Adjustment
1. Enter the service mode and select the service
adjustment "D01".
2. Adjust "D01" data value so that picture is centered.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D02".
3. Adjust "D02" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "EX2".
3. A black text box appears on the screen. (see
Figure
B. )
4. Adjust "EX2" data value so that text box is positioned
in the center of the screen.
Horizontal-Size Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D04" for H-size.
3. Adjust the "D04" bus data to get the proper H-size.
EW-Parabola
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D07" for EW parabola.
3. Adjust the "D07" bus data to get the proper vertical
straight line for both left and right side.
EW-Trapezium
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D08" for EW-Trapezium.
3. Adjust the "D08" bus data to get the best position
display.
EW-Corner
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D09" for EW-Corner.
3. Adjust the "D09" bus data to get the best linearity for
4 corner points.
Other Adjustments
1. Enter the service mode.
2. Adjust the following data values as listed below.
Figure B.
SERVICE
ADJUST
DATA(Hex)
POSITION
ITEM
32U-F810 32U-F500
OP1
OPTION1
F7
F5
OP2
OPTION2
F9
18
OP3
OPTION3
0F
0F
DISPLAY OF TEXT BOX
TEXT BOX
A
B
| A-B | / 2
SPEC INSPECTION:| A-B | / 2 <
= 5mm
Summary of Contents for 32U-F500
Page 13: ...13 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H MODEL 32U F500 CHASSIS LAYOUT ...
Page 14: ...14 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H MODEL 32U F810 CHASSIS LAYOUT ...
Page 15: ...15 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H MODEL 32U F500 BLOCK DIAGRAM ...
Page 16: ...16 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H MODEL 32U F810 BLOCK DIAGRAM ...
Page 22: ...27 32U F500 32U F810 26 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM AV Unit ...
Page 23: ...28 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM DF MODULE Unit ...
Page 24: ...29 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CONTROL Unit ...
Page 28: ...36 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit ...
Page 31: ...39 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Chip Parts Side ...
Page 34: ...42 32U F500 32U F810 6 5 4 3 2 1 A B C D E F G H PWB H DF MODULE Unit Wiring Side ...