7
32L-S500,32L-X2000
CL32S50,36L-X2000
CIRCUIT PROTECTION
The receiver is protected by a 5.0A fuse (F701),
mounted on PWB-C, wired into one side of the AC
line input.
X-RADIATION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal
deflection system, high voltage system, B+ system,
test the X-Radiation protection circuit to ascertain
proper operation as follows:
1. Apply 120V AC using a variac transformer for
accurate input voltage.
2. Allow for warm up and adjust all customer controls
for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to TP653 and make sure
that the voltmeter reads 11.83±0.7V (32L-S500,
CL32S50, 32L-X2000)/11.80±0.7V (36L-X2000).
5. Apply external 14.5V DC at TP653 by using an
external DC supply, TV must be shut off.
6. To reset the protector, unplug the AC cord and plug
the AC cord power on. Now make sure that normal
picture appears on the screen.
7. If the operation of the horizontal oscillator does not
stop in step 5, the circuit must be repaired before the
set is returned to the customer.
HIGH VOLTAGE CHECK
High voltage is not adjustable but must be checked
to verify that the receiver is operating within safe
and efficient design limitations as specified checks
should be as follows:
1. Connect an accurate high voltage meter between
ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 120V AC
line voltage, with a strong air signal or a properly tuned
in test signal.
3. Enter the service mode and select the service No.
"S21" and Bus data "01" (Y-mute on).
4. The voltage should be approximately, 32.8kV (at zero
beam).
If a correct reading cannot be obtained, check circuitry
for malfunctioning components. After the voltage test,
make Y-mute off to the normal mode.
INSTALLATION AND SERVICE INSTRUCTIONS
Note:
(1) When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2) Before performing adjustments, the TV set must be on at least 15 minutes.
Summary of Contents for 32L-S500
Page 6: ...6 32L S500 32L X2000 CL32S50 36L X2000 LOCATION OF USER S CONTROL ...
Page 15: ...15 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 PWB F PWB A ...
Page 17: ...17 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 PWB F PWB A ...
Page 19: ...19 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 21: ...21 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 27: ...27 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 29: ...29 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 31: ...31 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 33: ...33 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 35: ...35 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 37: ...37 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 39: ...39 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 41: ...41 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 43: ...43 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 45: ...45 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 47: ...47 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...
Page 49: ...49 32L S500 32L X2000 CL32S50 36L X2000 17 16 19 18 15 14 13 12 11 10 ...