21V-FS700S
3 – 18
NO
ADJUSTMENT POINT
WAVEFORM OR OTHERS
3
SUB-BRIGHTNESS
(to be done after
screen, white
balance adj)
(I2C BUS CONTROL)
ADJUSTMENT CONDITION / PROCEDURE
(1) In Window Pattern Signal condition.
(2) Using Minolta Color Analyzer CA-100, let the
gun point at
Dark White
position (as attach
drawing), adjust SUB-BRI Bus data until:
WINDOW PATTERN SIGNAL
Dark White
4
SUB-CONTRAST
(to be done after
screen, white
balance adj,
sub-brightness adj)
(I2C BUS CONTROL)
(1) In Window Pattern Signal condition.
(2) Using Minolta Color Analyzer CA-100, let
the gun point at
White
position (as attach
drawing), adjust
SUB-CON
Bus data until :
White
WINDOW PATTERN SIGNAL
5
BEAM
CURRENT
CHECK
(1) Receive the "Monoscope Pattern" signal.
(2) Press R/C to set Picture NORMAL condition.
(3) Connect the DC miliammeter between TP 603
( + ) & TP 602 ( - ) (Full Scale: 3mA Range).
(4) Beam current must be within :
1000 ± 100µA
Service
Luminance
mode
(cd/m2)
Upper limit
Lower limit
Enable
1.5
+0.5
-0.5
Disable
1.5
+1.5
-1.0
Tolerance (cd/m2)
Service
Luminance
mode
(cd/m2)
Upper limit
Lower limit
Enable
150.0
+10
-10
Disable
150.0
+20
-10
Tolerance (cd/m2)
Summary of Contents for 21V-FS700S
Page 63: ...21V FS700S 7 1 CHAPTER 7 CHASSIS LAYOUT 1 CHASSIS LAYOUT ...
Page 64: ...21V FS700S 8 1 CHAPTER 8 BLOCK DIAGRAM 1 BLOCK DIAGRAM MAIN UNIT ...
Page 65: ...21V FS700S 8 2 ...
Page 66: ...21V FS700S 8 3 2 BLOCK DIAGRAM CRT UNIT ...
Page 70: ...21V FS700S 11 2 2 SCHEMATIC DIAGRAM MAIN UNIT ...
Page 71: ...21V FS700S 11 3 ...
Page 73: ...21V FS700S 12 2 2 PWB A MAIN CHIP SIDE ...