background image

8

Ë

SERVICE ADJUSTMENT

VCO Adjustment

1. Connect a digital voltmeter between pin (44) of IC201

and ground.

2. Receive a good local channel.
3. Enter the service mode and select the service

adjustment "S10".

4. Adjust the data so that digital voltmeter reads 2.2V.
5. Adjustment is completed, remove the voltmeter,

return to "normal" mode.

RF AGC Adjustment

1. Receive a good local channel.
2. Enter the service mode and select the service

adjustment "S08".

3. Set the data value to point where no noise or beat

appears.

4. Select another channel to confirm that no noise or

beat appears.
Note 1: You will have to come out of the service

mode to select another channel.

Note 2: Setting the data to "00" will produce a black

raster.

Screen Adjustment

1. Connect a digital voltmeter between TP852 and

TP853 on the CRT Unit.
Note: These test points may not be provided.

Then connect the voltmeter to both ends of
R852 located near Q852 on the foil side.

2. Receive a good local channel.
3. Enter the service mode and select the service

adjustment "S03" and set the data value to "00" to
set the color level to minimum. (Record original data
code under adjustment "S03" before changing) You
may skip this step, if you selected a B/W picture or
monoscope pattern.

4. Select the service adjustment "S19" and adjust the

data value to "01", this turn off the luminance signal
(Y-mute).

5. Select the service adjustment "S04" and adjust data

value to obtain 0.17 volts on the digital voltmeter.

6. Adjust the master screen cotrol until the raster

darkens to the point where raster is barely seen.

7. Adjust the service adjustments "S11" red, "S12"

green and "S13" blue to obtain a good grey scale
with normal whites at low brightness level.

8. Select the service adjustment "S19" and reset data

to "00". Select the service adjustment "S03" and reset
data to obtain normal color level.

9. Remove digital voltmeter, and reset the master

screen control to obtain normal brightness range.

White Balance Adjustment

1. Receive a good local channel.
2. Enter the service mode and select the service

adjustment "S03" and set to "00" (minimum
color)(Record original data code under adjustment
"S03" before changing). "S03" does not have to be
adjusted, if you selected a B/W picture or monoscope
pattern.

3. Alternately adjust the service adjustment data of

"S14" and "S15" until a good grey scale with normal
whites is obtained.

4. Select the service adjustment "S03" and adjust data

to obtain normal color level.

Sub-Picture Adjustment

1. Receive a good local channel.
2. Make sure the customer picture control is set to

maximum.

3. Enter the service mode and select the service

adjustment "S01".

4. Adjust the data value to achieve normal contrast

range.

Sub-Tint Adjustment

1. Receive a good local channel.
2. Set customer tint control to center of it's range.
3. Enter the service mode and select the service

adjustment "S02".

4. Adjust "S02" data value to obtain normal flesh tones.

Sub-Color Adjustment

1. Receive a good local channel.
2. Make sure the customer color control is set to center

position .

3. Enter the service mode and select service

adjustment "S03".

4. Adjust "S03" data value to obtain normal color level.

19C140

Summary of Contents for 19C140

Page 1: ...er sales service only The contents are subject to change without notice CONTENTS SERVICE MANUAL POWER INPUT 120 V AC 60 Hz POWER RATING 69 W PICTURE SIZE 1 194cm2 185sq inch CONVERGENCE Magnetic SWEEP DEFLECTION Magnetic FOCUS Hi Bi Potential Electrostatic INTERMEDIATE FREQUENCIES Picture IF Carrier Frequency 45 75 MHz Sound IF Carrier Frequency 41 25 MHz Color Sub Carrier Frequency 42 17 MHz Nomi...

Page 2: ...meter should be checked periodically 3 High voltage should always be kept at the rated value no higher Operation at higher voltages may cause a failure of the picture tube or high voltage circuitry and also under certain conditions may produce radiation in exceeding of desirable levels 4 When the high voltage regulator is operating properly there is no possibility of an X radiation problem Every t...

Page 3: ... mechanical insulators and etc 3 To be sure that no shock hazard exists check for leakage current in the following manner Plug the AC cord directly into a 120 volt AC outlet Do not use an isolation transformer for this test Using two clip leads connect a 1 5k ohm 10 watt resistor paralleled by a 0 15mF capacitor in series with all exposed metal cabinet parts and a known earth ground such as electr...

Page 4: ...4 LOCATION OF USER S CONTROL 19C140 ...

Page 5: ...f the horizontal oscillator does not stop in step 5 the circuit must be repaired before the set is returned to the customer HIGH VOLTAGE CHECK High voltage is not adjustable but must be checked to verify that the receiver is operating within safe and efficient design limitations as specified checks should be as follows 1 Connect an accurate high voltage meter between ground and anode of picture tu...

Page 6: ... Use the reset function in the video adjustment menu to ensure customer controls are in their proper reset position 2 Service number selection Once in the service mode press the Ch up or Ch down button on the remote controller or at the set The service adjustment number will vary in increments of one from S01 to OP Select the item you wish to adjust 3 Data number selection Press the Vol up or down...

Page 7: ...03 No VERTICAL S20 ENERGY SAVE OFFSET 20 00 3F Must be set to 23 S21 D D E OFFSET 03 00 1F Must be set to 03 S22 OSD SETUP 00 00 03 Must be set to 00 S23 TUNER SETUP 00 00 01 Must be set to 00 OP OPTION 30 00 FF Must be set to 02 NECESSARY UNNECESSARY ADJUSTMENT NOTES PART REPLACED IC2001 IC2101 X CRT X IC201 X X Data is stored in IC2101 The adjustment is needed to compensate for characteristics o...

Page 8: ...aster screen cotrol until the raster darkens to the point where raster is barely seen 7 Adjust the service adjustments S11 red S12 green and S13 blue to obtain a good grey scale with normal whites at low brightness level 8 Select the service adjustment S19 and reset data to 00 Select the service adjustment S03 and reset data to obtain normal color level 9 Remove digital voltmeter and reset the mas...

Page 9: ... measured with 1000µ V B W or Color signal WAVEFORM MEASUREMENT CONDITIONS 1 Photographs taken on a standard gated color bar signal the tint setting adjusted for proper color The wave shapes at the red green and blue cathodes of the picture tube depend on the tint color level and picture control 2 indicates waveform check points See chart waveforms are measured from point indicated to chassis grou...

Page 10: ...10 6 5 4 3 2 1 A B C D E F G H CHASSIS LAYOUT NORMAL PR701 C708 19C140 ...

Page 11: ...11 6 5 4 3 2 1 A B C D E F G H BLOCK DIAGRAM 19C140 ...

Page 12: ...12 8 7 10 9 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM MAIN 1 Unit 19C140 ...

Page 13: ...13 17 16 19 18 15 14 13 12 11 10 19C140 ...

Page 14: ...14 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit 19C140 ...

Page 15: ...15 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Wiring Side PRINTED WIRING BOARD ASSEMBLIES 19C140 ...

Page 16: ... G H PWB A MAIN Unit Chip Parts Side n f r n n n n n n n b n n n n n n n f f f f f f f f f f n n r n r n n n b b b b n n r n b r r r n r n r b r r r r r r r r r r n r n n n f f n n n b n n b b b f f f n n n n f n n n n n 19C140 ...

Page 17: ...17 6 5 4 3 2 1 A B C D E F G H PWB B CRT Unit Chip Parts Side PWB B CRT Unit Wiring Side b b b b b b b b b b b b b b b b b 19C140 ...

Page 18: ...B p U D651 VHD1SS244 1Y X Diode AB p U D653 RH EX0667GEZZY X Zener Diode 27V AB D661 RH DX0468CEZZ X Diode AB U D701 RH DX0490CEZZY X Diode AB U D702 RH DX0490CEZZY X Diode AB U D703 RH DX0490CEZZY X Diode AB U D704 RH DX0490CEZZY X Diode AB D707 VHD1SS119 1Y X Diode AA D708 VHD1SS119 1Y X Diode AA D709 RH DXA006WJZZ X Diode AB D712 RH DX0487CEZZY X Diode AB D717 RH EX0616GEZZY X Zener Diode 5 6V ...

Page 19: ...nued PWB A DUNTKA358WEX9 CONTROL EL Electrolytic M Poly Metalized Polypro Film CAPACITORS Ref No Part No Description Code C706 RC KZ0092GEZZA X 3300p AC250V Ceramic AB C717 VCKYPA2HB472K X 4700p 500V Ceramic AB C723 RC EZ0638CEZZ X 33 160V EL AC C725 RC EZ0724CEZZ X 100 160V EL AC C726 VCKYPH3DB561K X 560p 2kV Ceramic AB C727 VCKYPA2HB472K X 4700p 500V Ceramic AB U C730 VCEA0A1CW108M X 1000 16V EL...

Page 20: ... 1 8W Carbon AA p R655 VRS CY1JF103JY X 10k 1 16W M Ox AA R659 VRN RL3AB3R3J X 3 3 1W M Film AB R661 VRN RL3ABR47J X 0 47 1W M Film AB R662 VRD RA2BE102GY X 1 0k 1 8W Carbon AA U R702 RR DZ0049CEZZY X 3 9M 1 2W Solid AB U R703 VRW KP3HC1R8K X 1 8 5W Cement AB U R705 VRN RL3ABR39J X 0 39 1W M Ox AB U R706 VRN RL3ABR39J X 0 39 1W M Ox AB U R707 VRD RM2HD270JY X 27 1 2W Carbon AA U R708 VRS CY1JF102J...

Page 21: ... K0202PEZZ X SWITCH AB S2502 QSW K0202PEZZ X SWITCH AB S2503 QSW K0202PEZZ X SWITCH AB S2504 QSW K0202PEZZ X SWITCH AB S2505 QSW K0202PEZZ X SWITCH AB FB351 RBLN 0047CEZZY X FERRITE BEAD AB FB601 RBLN 0047CEZZY X FERRITE BEAD AB FB2002 RBLN 0037CEZZY X FERRITE BEAD AB JA409 RBLN 0047CEZZY X FERRITE BEAD AB Ref No Part No Description Code J903 QJAKE0211CE09 X RCA JACK WHITE AB J905 QJAKE0211CE04 X ...

Page 22: ...REW CAB AA TINS B244WJZZ X OPERATION MANUAL RRMCG1324CESC X R C GUN AH TCAUS3000GJZZ X CAUTION LABEL AA TGAN A216WJN1 X WARRANTY CARD AB MISCELLANEOUS PARTS SUPPLIED ACCESORRIES SUPPLIED ACCESORRIES PACKING PARTS Ref No Part No Description Code SPAKCB315WJZZ X PACKING CASE SPAKP0102GJZZ X LAMIFOAM AC SPAKX0003GJZZ X PACKING FOAM AG SSAKA0101GJZZ X PLASTIC BAG AB 1 CCABA0108WEJ5 X CAB A ASSY 1 1 No...

Page 23: ... to fix the top side of packing case Packing Case FRONT Buffer Material Wrapping Paper Polyethylene Bag Operation Manual Infrared R C Unit Batteries MARK Not replacement items Use 10 staples to fix the bottom side of packing case 19C140 ...

Page 24: ...this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP ELECTRONICA MEXICO S A DE C V Quality Reliability Control Center Blvd SHARP No 3510 Parque Industrial Rosarito Playas de Rosarito México B C 22710 19C140 ...

Reviews: