v. 04/14A
7
PRESSURE
W
ASHER
OPERA
T
OR’S MAN
U
AL
Y INSTRUCTIONS
Attach the high
pres sure hose to the spray
gun using teflon tape on hose
threads.
STEP 3: Release the coupler col lar
and push the nozzle until the collar
clicks. Pull the nozzle to make sure it
is seated properly.
STEP 5: Connect the high pres sure
hose to the pump discharge fitting. Push
cou pler collar forward until secure.
STEP 2: Pull the spring-load ed col lar
of the wand coupler back to in sert your
choice of pres sure noz zle.
STEP 6: Connect garden hose to the
cold water source.
STEP 7: Connect the garden hose
to pump wa ter inlet. In spect inlets.
CAUTION: Do not run the pump
without wa ter or pump damage
will result.
Safety
Latch
Spray
Gun
High Pressure
Hose
Wand
Coupler
Soap
Nozzle
Pressure
Nozzle
Wand
Coupler
Wand
Collar
Discharge Fitting
High Pressure Hose
Cold
Water
Source
Garden
Hose
Coupler Collar
STEP 4: Remove shipping cap
and install oil dipstick. Check
pump oil level by using dip stick
or observe oil level in oil win-
dow (if equipped). Use 30 wt.
non detergent oil.
DipStick
Oil Window
Pump
Water Inlet
Garden
Hose