96-720, 97-708, 97-709, 97-710 • REV. 8/04
9
PRESSURE W
ASHER
OPERA
T
OR’S MANU
AL
SHUTTING DOWN AND CLEAN-UP
STEP 1: Remove deter-
gent suction tube from
container and insert into
one gallon of fresh water.
Slide nozzle forward for
low pressure or use black
detergent nozzle. Pull trig-
ger on spray gun and si-
phon fresh clean water for
one minute.
STEP 2: Turn off machine
by turning switch to “OFF”
switch.
STEP 5: Disconnect the
garden hose from the wa-
ter inlet on the machine.
STEP 6: Disconnect the
high pressure hose from
high pressure outlet.
STEP 7: Engage the
spray gun safety lock.
STEP 4: Press trigger to re-
lease water pressure.
Pump
Water
Inlet
High Pressure Outlet
Safety
Latch
STORAGE
CAUTION
Pump Storage
CAUTION: Always store your pres-
sure washer in a location where the
temperature will not fall below 32°F
(0°C). The pump in this machine is
susceptible to permanent damage if
frozen.
FREEZE DAMAGE IS NOT COVERED BY
WAR-
RANTY.
If you must store your pressure washer in a location
where the temperature is below 32°F, you can minimize
the chance of damage to your machine by draining your
machine as follows:
1.
Stop the pressure washer and detach supply hose
and high pressure hose. Squeeze trigger of spray
gun to drain all water from the wand and hose.
2.
Restart pressure washer and let it run briefly (about
5 seconds) until water no longer discharges from
the high pressure outlet.
STEP 3: Turn off water
supply.
On/Off
Switch