Modes
Each envelope has five different modes. To change mode, click
the corresponding channel's Mode button
[B]
. The two mode
LEDs
[C]
indicate the current mode:
02. Gated
The input accepts gate signals to generate
an attack-sustain-release envelope type.
01. Triggered
A rising edge triggers a one cycle envelope.
Time & Symmetry
Rather than having a classic attack-decay approach, the Triple
Steeple offers control of each envelope's timing and symmetry.
The time parameter, set via the Time potentiometer
[D]
and CV
input
[3]
, is the sum of the attack and decay time. Modifying
the time parameter will change the attack and decay time by the
same amount.
The symmetry parameter defines the ratio of attack and decay
times via the Symmetry potentiometer
[A]
. Fully counterclo-
ckwise, the envelope has zero attack time, and there is only
decay. Turning the potentiometer clockwise reduces the decay
time as the attack increases. With the Symmetry potentiometer
[A]
set at noon, the envelope is symmetrical (equal attack-decay
times). When the Symmetry potentiometer
[A]
is fully clockwise,
the envelope has an attack-only behavior without decay.