CONFIGURATION TOOL
This section describes the use of the 833811-00 Fuel Flow Configuration Tool. The AIS-380 is to be
configured on a test bench using the configuration tool prior to installation in the aircraft. Below is a list of the
equipment needed and the instructions for installing and configuring the AIS-380 with the configuration tool.
Equipment List
Installation Requirements for PC
•
+18 V to +28 V DC Power Supply
•
Windows XP SP3 or Windows 7
•
CK833811 Configuration Kit for 833811*
•
1 MB hard disk space
•
Desktop or Laptop PC with serial port or
USB adapter if no serial port is available
•
Intel® Pentium® Processor, 1.6 GHz
minimum
•
500 MB RAM minimum
* Contact Shadin Tech Support to obtain CK833811:
Web:
www.shadin.com
E-mail:
Phone:
(952) 927-6500 or
(800) 388-2849
The software and the cable required for this tool are included in the kit. Alternatively, a cable configured per
Figure 5 below can be built to interface the AIS-380 to the PC. The software can be acquired separately from
Shadin Tech Support.
+28 VDC
Ground
RS-232 Transmit
RS-232 Receive
2
1
34
19
2
5
3
Ground
44-Pin Female
High Density D-Sub
(Mating connector to
AIS-380)
9-Pin Female
Standard D-Sub
(Mating connector to
PC RS-232 Port)
To Power Supply
+18 to +28 VDC
Figure 5: Field Configuration Cable