REPLACING THE ABRASIVE NOZZLE

Ensure the air supply is disconnected before performing this operation.
1.  Pull the trigger of the gun as a precautionary measure.
2.  Unscrew the end cap and withdraw the ceramic nozzle.
3.  Replace with the nozzle of your choice and carefully thread the end 

cap back on to the gun, taking great care NOT to cross thread the fine 
thread.

NOTE: Should it be necessary to change the air nozzle, first remove the
abrasive nozzle as described above. A box spanner will be
required to unscrew and withdraw the air nozzle.

MAINTENANCE

Before use, check to ensure that all parts are serviceable, including the air
inlet hose and rubber gloves.

Ensure the air vent foam filter is in place.

The swivel clamps, securing the lid, must be secure so as not to allow the 
lid to open during operation. The build up of air pressure within the cabi-
net could force the lid open, allowing abrasive to escape. This is not only 
wasteful, but could be a health hazard.

Ensure the filters are serviceable and seated correctly.

Ensure you comply with all precautions regarding the use of compressed 
air, and air compressor operation.

WWW.SGS-ENGINEERING.COM

Summary of Contents for SSB100

Page 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SSB100 SHOT BLAST CABINET...

Page 2: ...re res piratory disease Always use recommended abrasives Abrasives used in this unit may be covered by COSHH INVENTORY A Foam Vent Filter B Air Vent Cover C Spare protective film D Ceramic Nozzles 4 5...

Page 3: ...abinet and tighten Insert the circular foam filter into the recess in the Air Vent Cover and attach the cover to the rear of the cabinet as shown in Fig 3 having first prised out the plastic bung from...

Page 4: ...ir connections are secure and the pick up is correctly located beneath the grid before filling the cabinet with abrasive media Do not fill higher than the level of the grid NOTE PTFE tape is provided...

Page 5: ...e A box spanner will be required to unscrew and withdraw the air nozzle MAINTENANCE Before use check to ensure that all parts are serviceable including the air inlet hose and rubber gloves Ensure the...

Page 6: ...ining clips and test its operation by plugging the transformer into the mains TROUBLESHOOTING Excessive dust in the cabinet No dust extract device used Install dust extract device Air vent or overflow...

Page 7: ...17 25 Large Hose Clamp 902135 8 Window Retaining Strip 902118 26 Nozzle Adaptor Nut 902136 9 Protective Film 902119 27 Nozzle 4mm 902137 10 Air Vent 902120 28 Gun Assembly 902138 11 Foam Filter 902121...

Page 8: ...European Communities Directive s and Standard s PLACE DATE Signature Robert Wyatt Company Secretary Derby UK 24th MAY 2018 SGS Engineering UK Ltd SGS Engineering UK Ltd West Side Park Raynesway Derby...

Reviews: