SGM
GB
Hazer 400
5
Press the yellow button (TIMER ON/OFF) to activate the timer function for the knobs DURATION and
INTERVAL located on the top of the controller. Adjust the interval between each Hazer emission (within the
range from 10 to 200 seconds) by means of the INTERVAL control knob. Adjust the duration of each Hazer
emission (within the range of 5 to 100 seconds) by means of the DURATION control knob.
HCR-1:
Wireless remote controller with ¼” stereo plug for SGM Hazer 400. Attach the receiver’s magnetic
base to the Hazer. Plug the receiver’s cable into the Hazer’s remote control input. Using the sending unit,
your SGM Hazer can be operated from a distance at least 50 meters when under no obstruction. Start Hazer
emission by pressing the small button on the sending unit. Stop Hazer emission by pressing the large
button. Multiple SGM Hazers may be controlled using only one sending unit.
*The control of the master unit will override all other controllers when connecting the Hazer
machine via DMX*
8.
DMX
O
PERATION
The units HZ-300 and HZ-400 have on-board DMX control.
These models use 1 channel to control volume
output operation. Each channel has a value range of 0 to 255. The DMX channel is set on the rear panel of
the HZ-300 and HZ-400 by setting the dip switches to the desired channel.
If Channel A has a value from 0 to 5, the unit is OFF.
Between the values 6 to 255 the volume of fog output is regulated.
With 6 being the minimum
volume of fog produced and 255 approaching the maximum. The volume output rises as the DMX value is
increased.
Note:
The controls HC-1 and HCR-1 will be disabled when the Hazer is in DMX mode.
www.audiovias.com