value) to couple the stages together. Remove this capacitor and connect the ADSP
2
board
in its place. The board has coupling capacitors on its input and output.
First, capacitor C1338 is removed and the board is installed across the connections where
it was. The FT817 schematic shows it like this:
A cut should be made on either side of C1338 and C1338 should be removed.