Sfere PA19 Series User Manual Download Page 19

17

Appendix 1 Alarm items and units of relative alarm threshold

No.

Alarm item

Unit of alarm value

0

U--H

High voltage alarm

or

I--H

High current alarm

0.1V or 0.001A

1

U--L

Low voltage alarm

or

I--L

Low current alarm

2

dI1.H

Relay activates when first digital input

conducts.

Alarm value is not

needed to be set in

relay linkage mode.

3

dI1.L

Relay activates when first digital input

opens.

4

dI2.H

Relay activates when second digital

input conducts.

5

dI2.L

Relay activates when second digital

input opens.

6

dI3.H

Relay activates when third digital input

conducts.

7

dI3.L

Relay activates when third digital input

opens.

8

dI4.H

Relay activates when fourth digital

input conducts.

9

dI4.L

Relay activates when fourth digital

input opens.

Summary of Contents for PA19 Series

Page 1: ...applied to the following models PZ195U 2X1 3X1 5X1 AX1 9X1 PA195I 2X1 3X1 5X1 AX1 9X1 PZ195U 2K1 3K1 5K1 AK1 9K1 DK1 PA195I 2K1 3K1 5K1 AK1 9K1 PZ195U 2S1 9S1J PA195I 2S1 9S1J PZ195U 5XY1 AXY1 9XY1 PA...

Page 2: ...mode 8 5 3 System setting 11 5 4 Input setting 11 5 5 Relay output setting 11 5 6 Analog output setting 12 5 7 Communication setting 13 6 Common problems and troubleshooting 13 6 1 About communication...

Page 3: ...f meter The electrical parameter supplied to the meter should be within the rated range The following conditions may result in damage or abnormal operation to the device The voltage of auxiliary power...

Page 4: ...utput outline code 2 3 5 9 A PZ195U X1 Single phase LED PA195I X1 PZ195U K1 single phase LED 1 1 PA195I K1 PZ195U 2S1 single phase LED 1 4 2 PA195I 2S1 PZ195U 9S1 single phase LED 1 2 PA195I 9S1 PZ195...

Page 5: ...t out 2 Take off the fixed clip of meter 3 Insert the meter into the cutout 4 Push the fixed clip to fix the meter Outline code Pointer meter model Panel mm2 Cut out mm2 Installation depth mm 2 42 squ...

Page 6: ...ly connected to 0 10A if the current is larger than 10A please use diverter or holzer component 2 Voltage input directly connected to 0 1000V 3 Make sure the positive and negative terminal of voltage...

Page 7: ...urrent digital input and relay output User can press or button to switch between different interfaces in a cyclic order Main measurement display interfaces are as follows Measurement display interface...

Page 8: ...ing There are reading and programming modes in the meter 5 1 Reading mode In measurement display interface keep pressing Menu button for more than three seconds until appears then press button to ente...

Page 9: ...7...

Page 10: ...g menu is as follows If the parameters of third level data are modified please press button to save the modified data and return to secondary level If user press Menu button the modified data will not...

Page 11: ...Unit means A V means kA kV Input signal value 0 9999 User can not set this Unit of input signal value or Unit User can not set this A V mA mV Com munic ation Meter address 1 247 Baud rate 2400 9600bps...

Page 12: ...A 4 20mA 4 12 20mA 0 5mA 0 5V 1 5V 0 10V Lower limit value of analog output 0 DS 0 5 a a rated value FS DS 500 Upper limit value of analog output 0 5 a FS 1 2 a a rated value FS DS 500 Syste m param e...

Page 13: ...ld Unit of primary value is A V E g set input signal as 50 0A 75mV user can not change secondary value 50 0A 75mV First enter setting menu second press or button to select third press button to enter...

Page 14: ...corresponds to 4 20mA output First enter setting menu second press or button to select third press button to enter analog output setting menu Now press or button again to select specific item and pres...

Page 15: ...er such as subordinate machine address baud rate and check mode corresponds to the requirements of host computer If several meters on spot do not send data back please check whether the communication...

Page 16: ...ation sign will flash 6 2 Measured data is not correct First make sure that the meter has been input right voltage The multimeter is used for measuring voltage Electric quantity displayed on the meter...

Page 17: ...on Electrical feature Accuracy 0 2 0 5 defaulted Data refresh rate 1s Input Rated voltage value DC 75mV 1 5V 110V 220V 1000V etc Rated current value DC 4 20mA 1A 5A 10A 75mV Overload continuous 1 2 of...

Page 18: ...lectrostatic discharge surge immunity IEC 61000 4 2 III Radiated radio frequency electromagnetic field immunity IEC 61000 4 3 III Electrical fast transient burst immunity IEC 61000 4 4 Surge immunity...

Page 19: ...onducts Alarm value is not needed to be set in relay linkage mode 3 dI1 L Relay activates when first digital input opens 4 dI2 H Relay activates when second digital input conducts 5 dI2 L Relay activa...

Page 20: ...d control relay through function code 0x05 0x0F Address Format Data content Data instruction R W 0000 fixed address Bit First relay 0 off 1 closed R W Bit Second relay 0 off 1 closed R W Remotely cont...

Page 21: ...bytes Message example 0x01 0x01 0x01 0x03 0x11 0x89 Remark the register value in the slave response indicates the state of the relay Beginning from the lowest bit of the byte each number corresponds...

Page 22: ...losed Read data register value function code 0x03 0x04 Host request Frame structure addres s code function code data code CRC check code initial register address number of register Byte 1 byte 1 byte...

Page 23: ...x3A slave response frame structure address code functi on code data code CRC check code initial relay address relay action value byte 1 byte 1 byte 2 bytes 2 bytes 2 bytes message example 0x01 0x05 0x...

Page 24: ...inning from the lowest bit of relay action value each bit corresponds to a loop of relay output 1 indicates the relay is closed while 0 indicates the relay is cut off In the upper list relay action va...

Reviews: