INTEGRATED STORAGE COLLECTOR SFERASOL
TM
USE AND MAINTENANCE MANUAL
SFERASOL
TM
can be supplied without storage tank also. This is an ideal solution for
swimming-pools systems, systems with centralized storage and solutions in which
only primary circuit is needed.
The appliance without storage tank is supplied without the following:
- Water storage tank
- Heat exchanger
- Expansion pot
- Circulating pump
- Differential thermostat (
SFERASOL
TM
panel is supplied with two sensors, one al-
ready
connected the panel and the other to be connected inside the tank, which will be
fi
tted in case of swimming-pools systems, inside the thermal exchanger)
- Thermal
fl
uid. (Primary circuit will be closed and will be charged, but regarding
TOTAL primary circuit , necessary quantity of thermal liquid shall be quanti
fi
ed de-
pending on the realized system).
Regarding
SFERASOL
TM
without storage tank, always consider that dimensioning is
not made by Sferasol S.r.l., so any damages occurred or any malfunctioning to the
fi
nal system shall not be attributable to Sferasol Energy S.r.l.
All missing components can be supplied by Sferasol Energy S.r.l. excepting the storage tank.
WARNING:
During installation of the system primary circuit must not be higher than
0,5 bar. Captators would be seriously damaged if the above value has over-
come.
During installation of a
SFERASOL
TM
panel without storage tank, follow instructions
relevant to
SFERASOL
TM
with storage water tank
Sferasol
TM