SFA SANIFLO SN4 071 Manual Download Page 10

10

11

EN-US

Programming
- 1 press on the «NORMAL» button = change to the next level 

indicated by a beep. This will increase the amount of inco-

ming water by two seconds.
- 1 press on the «ECO» button = change to the previous level 

indicated by a beep. This will decrease the amount of inco-

ming water by two seconds.
When the modification reaches the maximum or minimum 

level, the buzzer stops beeping. 
Description of the programming levels:

*S = operation of the solenoid valve (filling with clean water)

*P = pump operation (dilution and discharge)

Normal Cycle

S*

S+P*

S

S+P

S

S+P

Basic level

6 s

1 s

3 s

1 s

3 s

1 s

level +1

8 s

1 s

3 s

1 s

3 s

1 s

level +2

10 s

1 s

3 s

1 s

3 s

1 s

level +3

12 s

1 s

3 s

1 s

3 s

1 s

level +4

14 s

1 s

3 s

1 s

3 s

1 s

• To exit the programming mode automatically: no keys pres-

sed for 5 seconds = the green led turns on.
Note : The water consumption programmed remains in the 

memory even after the unit has been disconnected from the 

power supply.

6.2 MANAGEMENT OF THE BLACK WATER TANK

STATUS

ELECTRONIC KEYBOARD

USE

                       

BUZZER

     

LED

Buzzer

CAPTEUR

2

CAPTEUR

1

Sensor 1 : OFF

Sensor 2 : OFF

OFF green
OFF yellow

OFF

Normal

CAPTEUR

2

CAPTEUR

1

Sensor 1 : ON

Sensor 2 : OFF

ON green
ON yellow

OFF

Normal

CAPTEUR

2

CAPTEUR

1

Sensor 1 : ON

Sensor 2 : ON

OFF green
ON 

flashing red 

(«FULL» 

message 

visible)

4 beeps 

when a 

key is 

pressed.

3 extra cycles 

allowed.
Control panel 

then is locked 

until the tank 

is emptied.

Override of the system when 3rd status is reached
Pressing «NORMAL» for 5 seconds will return cycles to nor-

mal operation.

Attention: Prolonged use of the toilet when black 

water tank is full can lead to overflow.

LED 

yellow/red

LED 

green

7.2 WINTERIZING

• In the event of a long period without use, rinse the bowl 

then drain using the «EMPTY» button.
• Switch off the water and electricity supplies.
• Take the necessary measures to prevent damage caused 

by freezing.
• If using antifreeze, use only RV-antifreeze.

8. FAULT FINDING GUIDE

DISCONNECT ELECTRICAL POWER BEFORE 

WORKING ON THE UNIT !

FAULT 

DETECTED

PROBABLE CAUSES

REMEDIES

The cycle 

proceeds 

correctly, the 

motor turns but 

water in the 

bowl empties 

slowly or not 

at all.

The evacuation is 

clogged.

Dismount and clean the 

discharge pipe.

The cycle 

proceeds 

correctly, but 

some water 

remains in the 

bowl after a 

cycle.

The height of 

evacuation is too 

important.

Modify the installation.

The discharge pipe 

is pinched.

Check the route of the 

discharge pipe.

The motor 

rattles or 

crunches.

Foreign body into 

the bowl.

• Disconnect the motor 

supplies.

• Close water admission.

• Remove the motor unit.

• With a hook, withdraw 

all the matters being able 

to obstruct the rotation of 

macerator.

• With a tool, turn the 

turbine in the 2 directions 

until rotation is free.

• Re-connect the motor 

supplies and press on 

the pneumatic contactor 

to control the correct 

operation of unit.

• Open water supply.

If the macerator remains 

blocked, we recommend to 

call the SFA-Saniflo after-

sales service.

After the 

button on the 

control panel 

has been 

pressed, the 

cycle does not 

start.

Faulty program.

Faulty control 

panel.

Replace the control panel

Call the SFA-Saniflo after-

sales service.

The cycle starts 

but little water 

runs in the 

bowl.

The inlet filter of 

the solenoid valve is 

clogged.

Clean the filter of the 

solenoid valve.

 The water feed 

pipe is pinched.

Check the water admission 

pipe.

The cycle 

engages but 

water does not 

run in the bowl

The stop valve is 

closed.

Open the stop valve.

The solenoid valve 

is defective.

Change the solenoid valve.

7. CLEANING/MAINTENANCE

SN4 071

 can be used like any normal toilet and does not re-

quire any particular maintenance. 

7.1 CLEANING

• For cleaning, use normal sanitary products.
•  Do not use aggressive chemicals (such as acetone, pure 

bleach, etc.) that could damage the material of the bowl.

•  Use a suitable standard toilet brush; do not use scouring or 

abrasive pads.

Summary of Contents for SANIFLO SN4 071

Page 1: ...iones o preguntas técnicas por favor llame al soporte técnico de Saniflo sin cargo al 800 571 8191 USA This product must be installed in strict accordance with local plumbing codes Product should be installed by a licensed plumber Le produit doit être installé dans le respect des règlements sanitaires locaux Le produit doit être installé par un plombier qualifié El producto debe ser instalado en e...

Page 2: ...Quick installation guide Guide d installation rapide Guía de instalación rápida 3 7 English 8 Français 12 Español 16 ...

Page 3: ...mm 3 80mm 3 4 19mm 1 1 2 40mm 3 1 2 90mm 4 105mm 3 78mm 3 3 4 96mm 1 1 2 39mm 1 3 4 43mm 1 8 3mm SEA WATER PUMP SOLENOID VALVE POWER SOURCE MACERATOR TANK FULL SIGNAL CONTROL PANEL 4 105mm 3 78mm 3 3 4 96mm 1 1 2 39mm 1 3 4 43mm 1 8 3mm 50 100 2 1 SEA WATER PUMP SOLENOID VALVE POWER SOURCE MACERATOR TANK SIGNAL CONTROL PANEL 17 1 2 444mm 16 1 4 412 5mm mm 6 6 2 8 1 2 214mm 14 1 4 361mm 10 1 2 CONT...

Page 4: ...A WATER PUMP SOLENOID VALVE POWER SOURCE MACERATOR TANK FULL SIGNAL CONTROL PANEL 4 1 2 117mm 3 3 16 81mm 1 2 13mm 1 23mm 2 50mm 3 80mm 3 4 19mm 1 1 2 40mm 3 1 2 90mm A F B G C H D I E J x1 x2 x1 x2 x1 x2 x1 x2 x1 x2 C B A I 1 3 2 4 TO BLACK WATER TANK 1 2 14mm ...

Page 5: ...5 3 80mm 2 50mm H J F I ø 1 1 2 PVC Pipe WATER INLET 25 PSI MINIMUM PRESSURE 5 6 7 OPEN CLOSE ...

Page 6: ...e should be no less than 2 2 2 50 Clearance should be no less than 2 100 Sensor 50 Sensor SENSOR POSITIONING TANK Information on Sensors Sensors are provided with 14 cables If need to extend cable no specific wire is required You can extend up to 15 Ft LED 9 ...

Page 7: ...ere can not be any metallic part or another water tank within the clearance section of each sensor This can affect its sensitivity creating a false reading There shouldn t be another cable sensor or any wire above our sensors Sensors are not polarized return wire has to be plugged on negative terminal of control box or on ground metal frame ground continuity has to be checked first G Optional You ...

Page 8: ...RMANCE CURVE 0 10 20 30 40 50 60 70 80 90 100 L min m Ft 3 2 1 0 9 8 6 5 3 28 0 0 Gal min 2 6 5 3 7 9 10 5 13 2 15 8 18 5 21 23 7 26 12 V 24 V Vertical height Flow rate 3 4 DIMENSIONS 14 1 2 371 5mm 11 1 2 290mm 16 410mm 21 1 2 548mm 16 3 4 425mm 18 1 2 470mm 2 APPLICATION SN4 071 is a bowl fitted with a pump macerator to remove the sanitary effluent SN4 071 is for mobile unit use The unit has a h...

Page 9: ...to increase up to 8 more seconds The cycle will increase from 15 to 23 seconds To enter the programming mode Press the NORMAL and ECO buttons at the same time for at least 5 seconds The red LED flashes for 5 seconds and then goes off POWER ON POWER ON POWER ON used solely for that equipment It is advisable to add a 25 A fuse in a 12 Volt system and a 15 A fuse in a 24 Volt system DANGER Fire hazar...

Page 10: ...ssary measures to prevent damage caused by freezing If using antifreeze use only RV antifreeze 8 FAULT FINDING GUIDE DISCONNECT ELECTRICAL POWER BEFORE WORKING ON THE UNIT FAULT DETECTED PROBABLE CAUSES REMEDIES The cycle proceeds correctly the motor turns but water in the bowl empties slowly or not at all The evacuation is clogged Dismount and clean the discharge pipe The cycle proceeds correctly...

Page 11: ...ales Rep ASR at time of phone call 4 Subject to the Terms and Conditions above in no event shall the company be liable for any special incidental or consequential damage loss or injury of whatsoever nature or kind arising from or associated with the product or any component thereof Refer to section F for more details and information on warranty coverage exemptions 5 This warranty is transferable o...

Page 12: ...es que celles décrites dans cette notice sont à proscrire 3 DESCRIPTION 3 1 PRINCIPE DE FONCTIONNEMENT SN4 071 associe une pompe dilacératrice qui broie et vidange les eaux usées vers la caisse à eaux noires et une électrovanne qui remplit la cuvette d eau propre Son fonctionnement est commandé par un clavier électro nique 4 INSTALLATION Voir pages 3 à 7 L installation du SN4 071 doit être effectu...

Page 13: ... rallonger le câble jusqu à 15 Ft aucun fil spécifique n est nécessaire Repérer l emplacement des capteurs en vous aidant du sché ma 9 et des informations ci dessous Le capteur de niveau haut doit être placé à la distance mini male de épaisseur de la paroi 50 de l épaisseur du bord supérieur Le capteur de mi niveau doit être installé au milieu de la cuve en hauteur et en largeur L espace libre aut...

Page 14: ...ues Attention à ne pas utiliser d agents chimiques agressifs type acétone javel pure etc qui pourraient dégrader la matière du bol Utiliser une brosse à toilette standard adaptée ne pas utili ser de tampon à récurer ou de tampon abrasif 7 2 HIVERNAGE En cas de non utilisation prolongée Rincer la cuvette à l eau douce puis vidanger à l aide de la touche EMPTY Couper ensuite l alimentation en eau Dé...

Page 15: ...nt de service après vente de SFA au moment de l appel téléphonique 4 Sous réserve des conditions générales ci dessus la Com pagnie ne pourra en aucun cas être tenue responsable pour tout dommage perte ou blessure spéciale accidentel ou consécutif de quelque nature que ce soit résultant de ou associé au produit ou à l un de ses composants Se reporter à la section F pour plus de détails et d infor m...

Page 16: ...critas en las especifi caciones Se prohíbe cualquier aplicación distinta a las descritas en estas instrucciones 3 DESCRIPCIÓN 3 1 PRINCIPIO DE FUNCIONAMIENTO SN4 071 combina una bomba trituradora que aplasta y vacía las aguas resi duales en el depósito de aguas negras y una válvula solenoide que llena la taza con agua limpia Su funcionamiento se controla mediante un teclado electró nico 3 2 DATOS ...

Page 17: ...clado no debe obstaculizar la tapa debien do encontrarse debiendo encontrarse a 4 ft máximo del cua dro de control Recortar un rectángulo de 3 x 2 en la pared Fijar el teclado horizontalmente Fijar el marco con ayuda de los clips 4 4 CONEXIÓN ELÉCTRICA La alimentación eléctrica del SN4 071 debe conectarse directamente al cuadro eléctrico y solamente debe servir para este aparato Se recomienda añad...

Page 18: ...a no utilizar un es tropajo de fregar o un estropajo abrasivo 7 2 INVERNAJE En caso de no utilizarlo durante largo tiempo lave la cube ta y luego vaciar con el botón EMPTY Corte la alimentación de agua y electricidad de SN4 071 Tome las medidas necesarias para evitar los daños causa dos por las heladas Si se usa anticongelante utilice únicamente anticongelante específico para autocaravanas Nota No...

Page 19: ...epresentante del servicio SFA en el momento de la llamada telefónica 4 Sujeto a los términos y condiciones anteriores en ningún caso la Compañía será responsable de cualquier daño espe cial incidental o consecuente pérdida o lesión de cualquier tipo que surja de o en relación con el producto o cualquiera de sus componentes Consulte la sección F para obtener más detalles e infor mación sobre las ex...

Page 20: ...ssous United States Canada SFA SANIFLO INC SFA SANIFLO INC 105 Newfield Avenue Suite A 500 Jamieson Parkway Unit 5 Edison NJ 08837 Cambridge ON N3C 0G5 Toll Free 1 800 571 8191 Numéro sans frais 1 800 363 5874 Telephone 1 732 225 6070 Téléphone 1 519 824 1134 Fax 1 732 225 6072 Télécopieur 1 519 824 1143 E mail sfasales saniflo com Courriel ventes saniflo ca Web Site www saniflo com Site Web www s...

Reviews: