background image

0

3

6

9

12

15 max

feet / pieds

30

60

120

180

240 270

300

feet / pieds

SANIACCESS 

115 V - 60Hz - 1/2 HP 
IP44 - MAX. 4.5 Amps - 

 

feet/pieds

50

60

70

80

90

100

110

120 l/min

15

20

25

30 US galon/min

VER

TICAL DIST

ANCE

(DIST

ANCE VER

TICALE)

FLOW RATE 

(DÉBIT)

15

12

9

6

3

0

H

x1

E

x2

F

x2

G

x4

G

x4

G

4

I

x1

K

x1

J

x1

R

x2

P

x1

O

N

x4

M

x2

L

x2

C

US

1-1/4"

18-3/4"

13-1/8"

10-3/4"

3/4"

1-3/4"

1-5/8"

8-7/8"

6-3/4"

1-5/8"

7-1/4"

17-1/4"

C

x1

C

1

A

x1

A

x1

B

x1

A

B

x1

D

x1

D

x1

N

C

B

L

M

D

M

B

L

M

C

D

M

1" PVC 

(32 mm)

x2

N

A

L

B

L

C

M

M

D

B

L

Q

x1

x3

20x32

25x40

32x55

50x70

90x110

M

x2

x4

P

x1

O

x3

N

x4

¾" PVC 

(28 mm)

¾" CPVC 

(22 mm)

Summary of Contents for SaniAccess 3

Page 1: ...support toll free at 800 571 8191 USA or 800 363 5874 CDN Pour le service client les retours ou toute question technique merci d appeller le service technique de Saniflo au numéro suivant 800 571 8191 USA or 800 877 8538 CDN This product must be installed in strict accordance with local plumbing codes Product should be installed by a licensed plumber Le produit doit être installé dans le respect de...

Page 2: ...SANI 3 Ø 2 drain Ø 1 drain max 15 feet Ø or 1 discharge Ø1 vent Ø drain 1 max 18 3 3 4 4 max 18 1 2 2 6 5 7 Optional extension pipe for installing macerator behind a wall ...

Page 3: ...ISTANCE DISTANCE VERTICALE FLOW RATE DÉBIT 15 12 9 6 3 0 H x1 E x2 F x2 G x4 G x4 G 4 I x1 K x1 J x1 R x2 P x1 O N x4 M x2 L x2 C US 1 1 4 18 3 4 13 1 8 10 3 4 3 4 1 3 4 1 5 8 8 7 8 6 3 4 1 5 8 7 1 4 17 1 4 C x1 C 1 A x1 A x1 B x1 A B x1 D x1 D x1 N C B L M D M B L M C D M 1 PVC 32 mm x2 N A L B L C M M D B L Q x1 x3 20x32 25x40 32x55 50x70 90x110 M x2 x4 P x1 O x3 N x4 PVC 28 mm CPVC 22 mm ...

Page 4: ...E E F F G H 3 Q P 4 6 5 H ...

Page 5: ...1 ed Close é Fermé 1A 1B 1C min 6 Recommended 8 1Ab I J N O R O O Connecting fixtures can be connected to either side K N ...

Page 6: ...3 4 2 5 Access to Blade System ...

Page 7: ...1 5 6 3 4 2 Microswitch Capacitor Access to Pressure Sensing System ...

Page 8: ...ANIFLO INC SFA SANIFLO INC 105 Newfield Avenue Suite A 1 685 Speedvale Avenue West Edison NJ 08837 Guelph ON N1K 1E6 Toll Free 1 800 571 8191 Toll Free 800 363 5874 English Numéro sans frais 800 877 8538 Français Telephone 1 732 225 6070 Téléphone 519 824 1134 Fax 1 732 225 6072 Télécopieur 519 824 1143 E mail sfasales saniflo com Courriel sales saniflo com Web Site www saniflo com Site Web www sa...

Page 9: ...ng sweeping 90 degree elbows or two 45 degree elbows back to back to create the 90 degree turn 6 When the point of discharge into the soil stack is lower than the base of the unit a vacuum relief valve may need to be fitted at the highest point of in the pipe run in order to avoid siphonage 7 The macerating unit cannot accept without damage the disposal of sanitary items such as condoms tampons san...

Page 10: ... shower tray would be placed Note The actual distance between the p trap of the additional fixture and the macerating unit determines the necessary clearance to install the p trap and elevation required to ensure a minimum gravity flow of 1 4 inch per foot Therefore the further the pump is away from the connecting fixture the higher the platform would need to be raised considering the gravity fall re...

Page 11: ...ENANCE For qualified personnel only 1 If the unit needs to be opened or if the motor needs to be removed please pry open the lid for easy access There will be a gasket in between the lid and the casing which prevents any leakage in the unit 2 Note that the motor is filled with dielectric oil Do not remove it or replace with regular oil Please note that the distributor purposely does not keep seals b...

Page 12: ...ge s4He customer must produce proof of purchase to validate exchange LIMITATIONS 1 Fill and flush mechanism are guaranteed as per OEM warranty only 2 Vitreous china are guaranteed only for a factory defect 3 Cost of disconnection and reconnection ie labor charges are not covered by the warranty and are end users responsibility 4 Cost of mail or freight when a part or parts of the system have to be...

Page 13: ...drainage menant à la pompe doit avoir au minimum 1 4 po de pied Tout tuyau de déversement horizontal doit aussi avoir cette hauteur minimale 9 La longueur totale du tuyau de décharge doit être d au moins 3 pieds combinés avant le déversement dans la colonne de renvoi plus grande 10 La tuyauterie de l appareil au point d évacuation ne doit jamais être installée avec une pente diagonale ascendante I...

Page 14: ...STÈME D AÉRATION Cet appareil doit être ventilé Il possède une calotte de 1 po en haut de la couverture dédiée à cette connexion L appareil doit être relié au système d aération conformément auxréglementationslocales Placezlecoude 90 K sur la calotte connectez ensuite votre tuyauterie d aération et serrez avec les colliers N Tous les appareils connectés au système doivent aussi être ventilés Atten...

Page 15: ...rrait en résulter une inondation XIII L ACCÈS AUX COMPOSANTS PRINCIPAUX uniquement personnel qualifié L unité de macération est très fiable et pour une utilisation normale la fourniture de plu sieurs centaines de milliers de cycles est assurée Cependant il peut exister des cas où une intervention peut être nécessaire AVERTISSEMENT Avant d entreprendre des travaux d entretien ou de dépan nage il faut...

Page 16: ...ICTIONS 1 Les mécanismes de chasse et de remplissage du réservoir sont garantis par le fabricant d origine seulement 2 La porcelaine est garantie seulement contre les défauts de fabrication 3 La garantie ne couvre pas les frais de branchement et rebranchement de l installation c à d les frais de main d œuvre qui sont à la charge du client 4 La garantie ne couvre pas les frais d expédition ou de tr...