DESCRIPTION
SANICOMPACT
®
Star
/SANICERAMIC 3
®
is a
wall hung WC pan fitted with a pump macerator.
The
SANICOMPACT
®
Star
/SANICERAMIC 3
®
can only be installed with the special support
brackets supplied.
SANICOMPACT
®
Star
/
SANICERAMIC 3
®
is for use in a domestic
environment.
Installed and used correctly,
SANICOMPACT
®
Star
/SANICERAMIC 3
®
will give reliable and
consistent service.
Please note the following warning signs:
«
» Possible danger to personnel,
«
» Warning of possible electrical hazards,
«
WARNING
» This is a general warning that
failure to follow instructions could result
in poor functioning of the unit.
PRINCIPLES OF OPERATION
SANICOMPACT
®
Star
/SANICERAMIC 3
®
is
controlled by an electronic program with two
functions.
•
It has a macerating and pumping function.
To start press one of the two grey sections
(light grey: short flush, dark grey: long flush)
of the flush button integrated to the bowl.
• The pumping only cycle cleans the washbasin
waste. This is an automatic operation that will
activate as long as water from the washbasin
enters the unit.
2
LIST OF ACCESSORIES SUPPLIED
3
DIMENSIONS
4
TECHNICAL DATA
Applications
évacuation WC
évacuation lave-mains
Type C45
Maximum Vertical Pumping
3 m
Voltage
220-240 V
Frequency
50 Hz
Normal Power Rating
500 W
Maximum current consumption 2,5 A
Medium water temperature
35°C
Electric Class
I
Degree of protection
IP44
Net Weight (with frame)
28 Kg
WARNING:
Only installations conforming to
the above specifications are acceptable.
5
PERFORMANCE CURVE
6
VERTICAL/HORIZONTAL
PUMPING COMBINATIONS
7
INSTALLATION
PREPARATIONS
WARNING:
Before proceeding with the
installation of
SANICOMPACT
®
Star
/
SANICERAMIC 3
®
, ensure that the wall is
sufficiently robust to support the unit. (Each
fixing should have a tensile strength of 120 kg).
7a
HANGING THE PAN ONTO THE
SUPPORT FRAME
1 - Separate the pan and template
E
from
the frame (screwed together for transit
purpose).
2
- Assemble the threaded rods
A
with nuts
B
and washers
C
as per drawing 7a.
3
- Adjust the rod position to 50 mm + x the
wall thickness (eg. Stud partition and
tiles etc). See drawing 7a.
4 -
Adjust the lateral spacing of the rods.
5 -
Tighten the nuts fully.
6 -
Fit the plastic sleeves/inserts
D
onto
the threaded rods. (They protect the
ceramic from the metal threads).
7b
SETTING THE HEIGHT OF THE
SUPPORT FRAME
1
- Offer the frame and pan up to the wall.
2
- Adjust to a comfortable height using the
vertical threaded feet. (See drawing 7b).
3 - Remove the pan from the frame.
4
- Adjust the horizontal seating of the pan
support.
5
- Fully tighten the rod nuts.
7c
FIXING THE FRAME TO THE WALL
1 - Offer the support frame up to the wall.
2 - Ensure the seating is correct.
3
- Mark the screw holes with a pencil.
4
-
WARNING:
If your wall is not perfectly
vertical, use the six holes with a suitable
combination of packing/washers (as per
drawing 7c).
5 - Select the fixing appropriate for the
particular wall (we recommend mini-
mum size 8 x 120 mm wall fixings).
6
- Drill holes with appropriate drill.
7
- Fix the frame to the wall using the 4 or 6
holes accordingly.
8
-
WARNING:
The distance between the supporting
wall and the front of the support frame
should not exceed 100 mm.
Most importantly, the frame and the wall
should make a completely snug fit.
7d
WATER SUPPLY
1 - Run the water supply with copper pipe
in 15 mm, fitted with a 22 mm male
iron to connect to the
SANICOMPACT
®
Star
/SANICERAMIC 3
®
.
2 - The water supply pipe must be fitted in
the upper part of the frame.
3 -
WARNING:
It is essential to install an
isolation valve when fitting the pan.
4 - For correct rinsing of the bowl, the water
pressure entering the pan must be
minimum 1,7 bar.
UK
7e
DISCHARGE CONNECTION
1 - The discharge pipe should be either
copper or UPVC solvent weld pipe with
32 mm diameter.
2 - Put the end of the pipe through the
upper part of the frame.
3 - If the discharge pipework runs to a level
considerably lower than
SANICOMPACT
®
Star
/SANICERAMIC 3
®
unit, the resultant
syphoning effect can suck out the water
seal in the unit. Fitting an air admittance
valve (BBA approved) at the high point of
the pipe run will overcome this problem.
7f
CONNECTION OF WASH-BASIN
1 - Connect washbasin waste via 32 mm
or 40 mm CPVC pipe.
2 - Feed the waste pipe through either the
left or right hand holes provided.
3 -
IMPORTANT:
The waste pipe should
terminate in 40 mm to connect to the
special connector provided.
7g
ELECTRIC POWER SUPPLY
The electrical installation work must be car-
ried out by a qualified person.
The electrical installation work for the
equipment, in a bathroom, must be carried
out in accordance with the standards in force
in the country (NF C 15-100 in France).
The electric power supply as wired
beforehand by the installer must be class 1,
using 3 X 0.75 sq. mm wiring.
1 – Connect the electric power supply to a
triple screw connector (not supplied) in
an IP55 junction box (Sarel 01650 or
similar) installed beforehand, complying
with the following colours:
Brown = phase
Blue = neutral
Green/Yellow = earth.
2 – This connection must be used solely to
power the equipment, and it must be
protected by a high sensitivity 30mA
differential circuit breaker, set at 16 A.
3 -
ATTENTION:
the electrical junction box
must remain accessible after installation
of the toilet.
Fully illustrated step by step
instructions are downloadable
on www.saniflo.co.uk