Technical data

8.1.1 

CG 50 generator

Device data

Dimensions (W x D x H)

500 x 260 x 190 mm

Weight

5.2 kg

Device elements

Signal lights

4 LEDs

Processor

Microcontroller 8 bit

Controls

2 knobs

optional: COMBIPHON remote control 

(433 MHz, 10 mW)

Operating conditions

Operating temperature

-10 – 50 °C

Storage temperature

-15 – 60 °C

Protection rating

IP54 (when cover closed)

Permitted operating 

environments

outdoors

indoors

Non-permitted operating 

environments

in explosive areas

Power supply

Power supply

Pb battery, built-in and sealed

alternatively directly with 12 V=

Operating time, typical

10 h

Operating performance

86.4 Wh

Operating voltage

12 V

Nominal capacity

7.2 Ah

Charging time

9 h

Charging temperature

0 – 40°C

Charging voltage

12 V

Charging current

1.3 A

Charger

AC/DC adapter L

optional: Vehicle cable L

Summary of Contents for COMBIPHON

Page 1: ...12 09 2017 a 107543 en COMBIPHON Operating Instructions...

Page 2: ...COMBIPHON system Fig 1 CG 50 generator in case with accessories Fig 2 Ports on case AC DC adapter L Tapper Remote control CG 50 generator Oscillator port Power port...

Page 3: ...CG 50 generator Fig 3 CG 50 generator displays and controls Intensity setting for tapper only Stopper LED Frequency LED Frequency adjuster Tapper LED Battery LED On off and intensity adjuster...

Page 4: ...following NOTICE Risk of damage to property Note Tips and important information Enumerated lists numbers letters are used for Instructions that must be followed in a certain order Lists with bullet p...

Page 5: ...8 5 Locating pipelines with the stopper 9 5 1 Functional principle 9 5 2 Using the stopper to locate pipes 10 5 3 After location 11 5 4 Cleaning the stopper 12 6 CG 50 generator with remote control o...

Page 6: ...II Contents 8 1 5 Remote control optional 19 8 2 Accessories 19 8 3 Declaration of conformity 19 8 4 Advice on disposal 20 9 Index 21...

Page 7: ...s approved by Hermann Sewerin GmbH may be used when performing repairs Changes or modifications to this product may only be carried out with the approval of Hermann Sewerin GmbH Use only Hermann Sewer...

Page 8: ...N system for the application specified in section 1 2 1 4 General safety information The COMBIPHON system was manufactured in accordance with all binding legal and safety regulations It corresponds to...

Page 9: ...the system com ponents are in good working order Never use damaged or defective components Dirty contacts and moisture can result in functional disturbanc es Clean and dry the electrical connections...

Page 10: ...vailable for the CG 50 generator external power source 100 240 V AC DC adapter L 12 V battery via vehicle cable L accessory Pb battery rechargeable lead acid battery built in and sealed The CG 50 gene...

Page 11: ...system 5 If the battery voltage drops below 10 V and there is no external power supply the CG 50 generator will switch to standby mode In standby mode the current is less than 7 mA and all the LEDs w...

Page 12: ...panel indicate the following operating statuses LED Colours Signal Operating status Tapper red constant tapper connected Stopper red constant stopper connected Disposable battery green constant genera...

Page 13: ...pper attached to a house service connection 4 1 Using the tapper to locate pipes Proceed as follows to use the tapper to locate pipes 1 Attach the tapper to the line a To do this place the fastening c...

Page 14: ...the intensity and frequency too high if you are locating a pipeline close to the tapper Vibrations can for example travel along the walls of buildings and make location difficult 7 Mark the course of...

Page 15: ...unction with a standpipe Fig 5 Stopper on standpipe 5 1 Functional principle When water is withdrawn from a hydrant the water column is set in motion The stopper slows down the water column at interva...

Page 16: ...he flushing adapter off the standpipe 4 Connect the stopper to the standpipe 5 Always turn the intensity adjuster on the stopper fig 5 all the way to the right initially lowest intensity 6 Connect the...

Page 17: ...on an underground hydrant a Remove the stopper from the standpipe b Remove the standpipe from the hydrant 5 Thoroughly clean the components of the stopper section 5 4 on page 12 6 Dry all parts or let...

Page 18: ...n the piston and cylinder a Remove the cylinder b Carefully pull the piston out of the cylinder making sure you keep it straight c Thoroughly rinse the piston and cylinder with low lime or distilled w...

Page 19: ...de gate and housing with low lime or distilled water e Thoroughly dry the intensity adjuster and slide gate Allow the housing to air dry f Re insert the slide gate and intensity adjuster g Secure the...

Page 20: ...on the tapper to the requirements as follows Up key increases the intensity of the tapper Down key reduces the intensity of the tapper Pause key pauses pulses Pause key again resumes pulse after paus...

Page 21: ...15 6 2 Operating the stopper with the remote control Only the pause key on the remote control works when operating the stopper Press the pause key to pause the pulses on the stopper Press the pause k...

Page 22: ...nal cannot be detected CG 50 pulse too weak increase intensity on CG 50 Tapper fastening to pipeline has come loose tighten fastening chain 7 3 Problems with the stopper Problem Cause Solution Stopper...

Page 23: ...vice for repair If the piston is blocked carry out the following steps 1 Cut off the water supply and switch off the CG 50 generator 2 Disconnect the connecting cable between the CG 50 gener ator and...

Page 24: ...0 C Storage temperature 15 60 C Protection rating IP54 when cover closed Permitted operating environments outdoors indoors Non permitted operating environments in explosive areas Power supply Power su...

Page 25: ...non adjustable Pulse frequency 1 s 1 6 s 8 1 4 AC DC adapter L Input 100 240 V 50 Hz 1 A Output 12 V 5 A 8 1 5 Remote control optional Range 30 m 300 m 8 2 Accessories Part Order number Standpipe DN...

Page 26: ...es Description of waste Allocated EWC waste code Device 16 02 13 Disposable battery rechargeable battery 16 06 05 20 01 34 End of life equipment Used equipment can be returned to Hermann Sewerin GmbH...

Page 27: ...ter remote control 14 stopper 9 10 L LED 6 O On off 6 Operating temperature 18 R Remote control 14 tapper intensity setting 14 S Stopper adjusting pulses 10 cleaning 12 components 12 connecting 9 cyli...

Page 28: ...w sewerin fr sewerin sewerin fr Sewerin Ltd Hertfordshire UK Phone 44 1462 634363 www sewerin co uk info sewerin co uk SEWERIN IBERIA S L Centro de Negocios Eisenhower Avenida Sur del Aeropuerto de Ba...

Reviews: