6
│ 3 CG 50 generator
3
CG 50 generator
The
CG 50
generator is permanently integrated in the case and
cannot be removed (fig. 1).
There is an optional remote control available for the
CG 50
gen-
erator.
3.1
Controls and displays
For an overview including the names of all the controls and dis-
plays, see the front cover flap (fig. 3). The frequency and intensity
of the signal used for the location process are set using the knobs
on the
CG 50
generator.
The LEDs on the control panel indicate the following operating
statuses:
LED
Colours Signal
Operating status
Tapper
red
constant
tapper connected
Stopper
red
constant
stopper connected
Disposable
battery
green
constant
generator switched on
flashing
battery charging
double flashing
trickle charge
red
flashing
undervoltage
Frequency red
flashing
generator generating
pulse
3.2
Switching the generator on and off
The
CG 50
generator is switched on and off using the on/off knob.
● Turn the on/off knob to the right until you overcome the slight
resistance. The generator is switched on.
● Turn the on/off knob to the far left until you overcome the slight
resistance. The generator is switched off.