Cable routing and shielding
Electrical installation
5.6
Cable routing and shielding
5.6.1
Installation material kit (part no. 1 824 139 5)
Each MOVIGEAR
®
drive unit
1)
in die-cast design is delivered with an accessory bag that
contains installation material for cable shielding:
•
A1: Installation material for line cables and hybrid cables:
2 x shield clamps with shield plate and screws to connect the shield of line cables
(SNI) or hybrid cables (outer shield).
•
A2: Conductive film:
2 x pieces of conductive film to wind around the braid shield. Use the conductive film
if required.
•
B: Installation material for control cables and data cables:
3 x shield clamp with screw to connect the shield of control cables or data cables
(STO, CAN, binary signals).
1) Exception: Not when all possible connections have been ordered as plug connectors.
3360276107
A1:
A2:
B:
2x
2x
4x
2x
3x
3x
M4x12
(1.4 - 1.6 Nm)
M4x10
(2.0 Nm)
M4x10
(2.0 Nm)
20mm
20mm
3x
2x
INFORMATION
For some installation variants, you do not need all the parts of the accessory kit.
The following examples apply to variants with die cast housing. You can identify units
with die cast housing by means of the type designation of the electronics cover, see
chapter "Unit Structure of the die-cast design/type designation".