Operating Instructions – MOVIGEAR® SNI-B
11
2
Operation
Safety notes
2.8
Operation
Systems with integrated MOVIGEAR
®
drive units must be equipped with additional
monitoring and protection devices according to the applicable safety guidelines, such as
the law governing technical equipment, accident prevention regulations, etc. Additional
protective measures may be necessary for applications with increased potential risk.
Changes to MOVIGEAR
®
drive units using the operating software are permitted.
The connection boxes must be closed and screwed on before the supply voltages are
connected to MOVIGEAR
®
drive units.
The unit may still be live and connected to the power supply even if the operation LEDs
and other display elements are no longer illuminated.
Mechanical blocking or internal safety functions of the unit can cause a motor standstill.
Eliminating the cause of the problem or performing a reset may result in the drive re-
starting automatically. If this is not permitted for the driven machine for safety reasons,
disconnect the unit from the supply system before correcting the fault.
Caution: Danger of burns: The surface temperatures of MOVIGEAR
®
drive units can be
more than 60 °C during operation.
5 minutes
WARNING
Do not touch live components and power connections immediately after separation of
the MOVIGEAR
®
drive units from the supply voltage because some capacitors might
still be charged.
Severe or fatal injuries.
• Wait at least for 5 minutes after the supply voltage has been switched off.