10
Data exchange with higher-level controller
F process input data
Manual – MOVISAFE
®
CS..A Safety Card
83
Byte Bit Name
Value Description
1
0
F-DI00
0
Process value of digital, safe digital input F-
DI00, no voltage or error is present.
1
Process value of digital, safe digital input F-
DI00, voltage is present.
1
F-DI01
0
Process value of digital, safe digital input F-
DI01, no voltage or error is present.
1
Process value of digital, safe digital input F-
DI01, voltage is present.
2
F-DI02
0
Process value of digital, safe digital input F-
DI02, no voltage or error is present.
1
Process value of digital, safe digital input F-
DI02, voltage is present.
3
F-DI03
0
Process value of digital, safe digital input F-
DI03, no voltage or error is present.
1
Process value of digital, safe digital input F-
DI03, voltage is present.
4
Reserve
5
Reserve
6
Reserve
7
Reserve
2
0
SOS1
0
The SOS1 drive safety function is not active, or
an error has occurred.
1
The SOS1 drive safety function is active.
1
Reserve
2
SSx1
0
The SSx1 drive safety function is not active, or
an error has occurred.
1
The SSx1 drive safety function is active.
3
SSx2
0
The SSx2 drive safety function is not active, or
an error has occurred.
1
The SSx2 drive safety function is active.
4
SDI1
0
The SDI1 drive safety function is not active, or
an error has occurred.
1
The SDI1 drive safety function is active.
5
SDI2
0
The SDI2 drive safety function is not active, or
an error has occurred.
1
The SDI2 drive safety function is active.
6
SLI1
0
The SLI1 drive safety function is not active, or an
error has occurred.
1
The SLI1 drive safety function is active.
7
SLI2
0
The SLI2 drive safety function is not active, or an
error has occurred.
1
The SLI2 drive safety function is active.
24842532/EN – 04/2018