![SEW-Eurodrive Movipro PZM2xA-A022-M13-00 Addendum To The Operating Instructions Download Page 16](http://html1.mh-extra.com/html/sew-eurodrive/movipro-pzm2xa-a022-m13-00/movipro-pzm2xa-a022-m13-00_addendum-to-the-operating-instructions_1250347016.webp)
2
Interface box
Electrical installation
Addendum to the Operating Instructions – MOVIPRO
®
– Accessories
16
2.8.4
X1 terminal strip of the interface box
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
V
O
2
4
D
G
N
D
+2
4
V
_C
0
V
2
4
_C
HT
1
HT
2
L
1
L
2
L
3
V
O24
D
GN
D
+24V
_C
0V
24_C
HT
1
HT
2
L
1
L
2
L
3
27021599719541387
Terminal strip X1 (power input terminal strip)
Terminal cross
section
Name
Function
[1]
VO24
DC 24 V output
0.2 – 6 mm
2
[2]
GND
Reference potential/DC 24 V output
[3]
+24V_C DC 24 V input
[4]
0V24_C 0V24 reference potential – input
[5]
HT1
Auxiliary terminal for additional voltage levels
(without internal function)
[6]
HT2
Auxiliary terminal for additional voltage levels
(without internal function)
[7]
L1
Supply system phase 1
0.2 – 10 mm
2
[8]
L2
Supply system phase 2
[9]
L3
Supply system phase 3
[10]
PE
PE connection
23106913/EN – 02/2018