![SEW-Eurodrive Movipro PZM2xA-A022-M13-00 Addendum To The Operating Instructions Download Page 11](http://html1.mh-extra.com/html/sew-eurodrive/movipro-pzm2xa-a022-m13-00/movipro-pzm2xa-a022-m13-00_addendum-to-the-operating-instructions_1250347011.webp)
2
Interface box
Mechanical installation
Addendum to the Operating Instructions – MOVIPRO
®
– Accessories
11
2.7
Mechanical installation
2.7.1
Minimum clearance
During installation, observe the minimum required clearances for connecting cables
and plug connectors, as well as for handling the actuating elements. Consult the
MOVIPRO
®
device's operating instructions in the "Mechanical installation" chapter and
the dimension drawing to obtain the dimensions for the required minimum clearances.
2.7.2
Mounting
Mount the interface box on the right side of the MOVIPRO
®
.
[1]
[2]
[4]
[3]
18014400571648267
[1]
MOVIPRO
®
[3]
Interface box
[2]
Interface box flange
[4]
M5 × 30 SW8 screws
Proceed as follows:
1. Connect the required connections to the front panel on the interface box, e.g.
AC 400 V supply line and DC 24 V backup voltage.
2. Connect the plug connector of the interface box to the plug connector of
MOVIPRO
®
.
3. Attach the interface box to MOVIPRO
®
by tightening the two M5 × 30 screws with
a tightening torque of 1.6 Nm – 1.8 Nm.
23106913/EN – 02/2018