230
Subfault: 25.6
Description: Incompatible device configuration
Response: Output stage inhibit
Cause
Measure
The data set in the device was copied from an-
other device, which differs from the current device
in the device family, power, or voltage.
– Check whether the configuration is correct and
repeat the startup, if necessary.
– Acknowledge the fault by manual reset with
parameter set acceptance. Setting under [Diag-
nostics] > [Status] > [Fault status] parameter
"Manual fault reset".
Replaceable memory module used by another
device. Power rating, device family, or voltage dif-
fers from the current device.
– Check whether the configuration is correct and
repeat the startup, if necessary.
– Acknowledge the fault by manual reset with
parameter set acceptance. Setting under [Diag-
nostics] > [Status] > [Fault status] parameter
"Manual fault reset".
The power section was replaced and differs in its
power rating or voltage from the original power
section.
– Check whether the configuration is correct and
repeat the startup, if necessary.
– Acknowledge the fault by manual reset with
parameter set acceptance. Setting under [Diag-
nostics] > [Status] > [Fault status] parameter
"Manual fault reset".
Subfault: 25.7
Description: NV memory initialization – error
Response: Output stage inhibit
Cause
Measure
Error initializing non-volatile memory system.
– Reset the device.
– If this occurs repeatedly, replace device. Con-
tact the SEW‑EURODRIVE Service.
Subfault: 25.10
Description: Power section configuration data – version conflict
Response: Output stage inhibit
Cause
Measure
Wrong version of configuration data of power sec-
tion.
Contact the SEW‑EURODRIVE Service.
Subfault: 25.12
Description: Power section configuration data – CRC error
Response: Output stage inhibit
Cause
Measure
Faulty configuration data of power section.
Contact the SEW‑EURODRIVE Service.
29129451/EN – 12/2019