4
Mechanical installation
AQ. adapter coupling
Assembly and Operating Instructions – Gear unit series R..7, F..7, K..7, K..9, S..7, SPIROPLAN
®
W
66
5.
AQA design:
Secure the coupling half using the set screw (see figure).
6. Check the position of the coupling half. The values for the distance "A" are listed in
the table in chapter "Setting standards and tightening torques (
7. Mount the motor onto the adapter, making sure that the claws of the two coupling
halves engage in each other.
ð
The force that must be applied when joining the two coupling halves is dissipa-
ted after final assembly, so there is no risk of any axial load being applied to ad-
jacent bearings.
4.10.2
Setting standards and tightening torques
Type
Coupling size
Distance A
mm
Screws
Tightening torque T
A
Nm
AQA
AQH
AQA
AQH
AQA /AQH 80 /1 /2 /3
19
44.5
M5
6 x M4
2
4.1
AQA /AQH 100 /1 /2
39
AQA /AQH 100 /3 /4
53
AQA /AQH 115 /1 /2
62
AQA /AQH 115 /3
24
62
M5
4 x M5
2
8.5
AQA /AQH 140 /1 /2
62
AQA /AQH 140 /3 /4
28
74.5
M8
8 x M5
10
8.5
AQA /AQH 160 /1
74.5
AQA /AQH 190 /1 /2
76.5
AQA /AQH 190 /3
38
100
M8
8 x M6
10
14
4.10.3
Permitted loads
CAUTION
Impermissibly high loads may occur when mounting a motor.
Possible damage to property.
• The load data specified in the following table are not to be exceeded.
The following figure shows the permitted force application points for the permitted
maximum weights:
X
F
R
9007199273254411
Motor's center of gravity
F
R
Overhung load
X
Distance from adapter flange -
motor center
21932786/EN – 05/2015