8
Technical data
Extended storage
Assembly and Operating Instructions – Gear unit series R..7, F..7, K..7, K..9, S..7, SPIROPLAN
®
W
147
Climate zone
Packaging
1)
Storage
2)
Storage duration
Tropical
(Asia, Africa,
Central and
South America,
Australia, New
Zealand exclud-
ing temperate
zones)
• Packed in contain-
ers
• With desiccant and
moisture indicator
sealed in the plas-
tic wrap
• Protected against
insect damage and
mildew by chemi-
cal treatment
• Roofed
• Protected against rain and snow
• Shock-free
Up to 3 years with regu-
lar checks of the pack-
aging and moisture indi-
cator (rel. humidity
< 50%)
Open
• Under roof and enclosed at constant
temperature and atmospheric humid-
ity (5 °C < ϑ < 50 °C, < 50% relative
humidity)
• No sudden temperature variations
• Controlled ventilation with filter (free
from dust and dirt)
• No aggressive vapors
• No shocks
• Protected against insect damage
2 years or more with
regular inspections
• Check for cleanness
and mechanical
damage during the
inspection
• Check corrosion pro-
tection
1) The packaging must be carried out by an experienced company using the packaging materials that have been explicitly specified for
the particular application.
2) SEW
‑
EURODRIVE recommends to store the gear units according to the mounting position.
21932786/EN – 05/2015