6
Operation
Status and error statuses
Operating instructions – ECDriveS
®
30
6
Operation
6.1
Status and error statuses
24 V
ECC-DBC-24-00
2
1
4
3
6
5
8
7
10
9
0 V
[5]
[4]
[3]
[2]
[1]
25852351627
[1]
LED "Stop"
[2]
LED "Hold"
[3]
LED "Start"
[4]
Operation LED
[5]
LED "Overtemperature"
The following table lists all LEDs with their main functions.
LED LED status
Description
[1]
0.2 seconds of flashing at an
interval of 0.4 seconds
Motor roller is not connected
Flashing at an interval of 1
second
Motor stopped by control due to error status
[2]
ON
Motor current limitation is active
Flashing and flickering
Blocking or overcurrent with limited PWM
[3]
Flash
RUN signal/s is/are on and flashing in sync is
proportional to the motor speed
[4]
ON with normal brightness
Input voltage is between 18 V and 31 V
FLASHES at an interval of
0.1 seconds
Input voltage is less than 18 V
ON with high brightness level Input voltage is higher than 31 V
[5]
ON
Calculated motor temperature exceeds 107 °C
28507088/EN – 11/2018