6
Cable specifications
Cable carrier installation
Addendum to the Operating Instructions – AC Motors with MOVILINK
®
DDI Interface
19
Type
LEHC 005796
LEHC 005770
LEHC 005771
LEHC 005772
LEHC 005773
Part number of bulk
cable, not prefabricated
28123336
28123344
28123352
28123360
28123379
Cross section
4 × 1.5 mm
2
4 × 2.5 mm
2
4 × 4.0 mm
2
4 × 6.0 mm
2
4 × 10 mm
2
[5] Cores
4 × 1.5 mm
2
4 × 2.5 mm
2
4 × 4.0 mm
2
4 × 6.0 mm
2
4 × 10 mm
2
Conductor
Stranded copper wire, bare
Single wire
0.15 mm
Single wire
0.15 mm
Single wire
0.15 mm
Single wire 0.2 mm
Single wire 0.2 mm
in accordance with DIN EN 60228 class 6
IEC 60228 Class 6
Diameter
3.0 mm
3.6 mm
3.75 mm
4.6 mm
5.8 mm
Insulation
Polypropylene
Colors
green yellow, black with label: U/L1; V/L2; W/L3
[6] Shield
Braided tinned cop-
per wires, 0.15 mm
Braided tinned cop-
per wires, 0.15 mm
Braided tinned cop-
per wires, 0.15 mm
Braided tinned copper
wires, 0.2 mm
Braided tinned copper
wires, 0.2 mm
Optical coverage at least 85%
[7] Outer cable jacket
Polyurethane, flame retardant, halogen-free
Color
Flat orange
Label
SEW-EURODRIVE
28123336
4 × 1.5 + 2 × 2 × 1C
+ 1 × Z50
SEW-EURODRIVE
28123344
4 × 2.5 + 2 × 2 × 1C
+ 1 × Z50
SEW-EURODRIVE
28123352
4 × 4.0 + 2 × 2 × 1C
+ 1 × Z50
SEW-EURODRIVE
28123360
4 × 6.0 + 2 × 2 × 1.5C
+ 1 × Z50
SEW-EURODRIVE
28123379
4 × 10 + 2 × 2 × 1.5C
+ 1 × Z50
LEHC005796 Rev.
0 E47543-LIL
LEHC 005770
Rev.0 E47543-LIL
LEHC 005771
Rev.0 E47543-LIL
LEHC 005772 Rev.0
E47543-LIL
LEHC 005773 Rev.0
E47543-LIL
AWM STYLE 21223 I/II A/B 80 °C 1000V FT1 Week/year of production
Diameter
15.7 mm
16.7 mm
17.0 mm
19.7 mm
22.1 mm
Electrical properties
Operating voltage
conductors V
0
/V
0.6 kV/1.0 kV
Operating voltage
according to UL
style 21223
Max. 1000 V
Surge impedance
coaxial cable
50 Ω ± 2 Ω
Mechanical properties
Bending radius
min. 3 × outer diameter for one-time installation
min. 5 × outer diameter for fixed installation
min. 10 × outer diameter for cable carriers
Travel speed
Max. 5 m/s
Acceleration
max. 20 m/s
2
Bending cycles
min. 5 × 10
6
Mass
332 kg/km
392 kg/km
444 kg/km
626 kg/km
827 kg/km
Thermal properties
Operating tempera-
ture
Fixed installation: -40 °C to +90 °C
Cable carrier installation: -30 °C to +90 °C
Operating tempera-
ture according to
cURus
Fixed installation: -40 °C to +80 °C
Cable carrier installation: -30 °C to +80 °C
Chemical properties
Oil resistance
DIN VDE 0282‑10/HD 22.10 S2
Flame retardant
UL 1581 section 1060 Vertical Flame Test (FT1)
CSA C22.2 No.3-92 Vertical Flame Test (FT1)
IEC 60332-1-2
Other features
29182654/EN – 10/2019