4
Electrical installation
Connection with plug connectors
Addendum to the Operating Instructions – AC Motors with MOVILINK
®
DDI Interface
12
4.2
Connection with plug connectors
The cable entry of the power and signal cables is installed using plug connectors.
Comply with the permitted bending radii of the cables.
4.2.1
Representation of connections
The wiring diagrams of the plug connectors depict the contact end of the connections.
4.2.2
Motor connection for motors with MOVILINK
®
DDI interface
The following table shows information about this connection:
Function
Motor connection for units with digital interface (MOVILINK
®
DDI)
Connection type
M23, male, male thread, TE Connectivity - Intercontec Products, series 723, SEW in-
sert, SpeedTec equipment, coding ring: without, protected against contact
Connection diagram
V
D
W
PE
C
U
DDI
A
B
Assignment
No.
Name
Function
U
U
Motor connection phase U
V
V
Motor connection phase V
W
W
Motor connection phase W
A
Reserved
Do not connect
B
Reserved
Do not connect
C
Reserved
Do not connect
D
Reserved
Do not connect
PE
PE
PE connection
1
DDI
MOVILINK
®
DDI
29182654/EN – 10/2019