8.0 Returning products for repair

Please contact a Setra application engineer (800-257-3872, 978-263-1400) before returning unit for repair to review 

information relative to your application. Many times only minor field adjustments may be necessary. When returning a 

product to Setra, the material should be carefully packaged and shipped prepaid to:

Setra Systems, Inc.

159 Swanson Road

Boxborough, MA 01719-1304

Attn: Repair Department

To ensure prompt handling, please supply the following information and include it inside the package or returned material:

•  Name and phone number of person to contact.

•  Shipping and billing instructions.

•  Full description of the malfunctions.

•  Identify any hazardous material used with the product.

NOTES:

Please remove any pressure fittings and plumbing that you have installed and enclose any required mating electrical 

connectors and wiring diagrams.

Allow approximately 3 weeks after receipt at Setra for the repair and return of the unit. Non-warranty repairs will not be 

made without customer approval and a purchase order to cover repair chargers.

Calibration Services

 

Setra maintains a complete calibrations facility that is traceable to the National Institute of Standards and Technology 

(NIST). If you would like to recalibrate or recertify your Setra pressure transducers or transmitters, please call our Repair 

Department at 800-257-3872 (978-263-1400) for scheduling.

9.0 Limited warranty & limitation of repair

SETRA warrants its products to be free from defects in materials and workmanship, subject to the following terms and 

conditions:  Without charge, SETRA will repair or replace products found to be defective in materials or workmanship within 

the warranty period; provided that:

a) the product has not been subjected to abuse, neglect, accident, incorrect wiring not our own, improper installation 

or servicing , or use in violation of instructions furnished by SETRA;

b) the product has not been repaired or altered by anyone except SETRA or its authorized service agencies;

c) the serial number or date code has not been removed, defaced, or otherwise changed; and

d) examination discloses, in the judgment of SETRA, the defect in materials or workmanship developed under normal 

installation, use and service; 

e) SETRA is notified in advance of and the product is returned to SETRA transportation prepaid.

Unless otherwise specified in a manual or warranty card, or agreed to in a writing signed by a SETRA officer, SETRA 

pressure and acceleration products shall be warranted for one year from date of sale.

The foregoing warranty is in lieu of all warranties, express, implied or statutory, including but not limited to, any implied 

warranty of merchantability for a particular purpose.

SETRA’s liability for breach of warranty is limited to repair or replacement, or if the goods cannot be repaired or replaced, to 

a refund of the purchase price.

SETRA’s liability for all other breaches is limited to a refund of the purchase price.  In no instance shall SETRA be liable for 

incidental or consequential damages arising from a breach of warranty, or from the use or installation of its products.

No representative or person is authorized to give any warranty other than as set out above or to assume for SETRA any 

other liability in connection with the sale of its products.

For all CE technical questions, contact Setra Systems, USA. EU customers may contact our EU representative Hengstler 

GmbH, Uhlandstr 49, 78554 Aldingen, Germany (Tel: +49-7424-890; Fax: +49-7424-89500). 

Summary of Contents for Model 730

Page 1: ...Model 730 Operating Instructions Setra Systems Inc 159 Swanson Road Boxborough MA 01719 800 257 3872 www setra com...

Page 2: ...ble capacitor within a small reference vacuum chamber As the pressure increases the diaphragm deflects and the gap between the electrode and diaphragm reduces causing an increase in the capacitance Th...

Page 3: ...to connect the NW16 flange to an NW10 flange on the system Use a Male 4 VCR or 8 VCR Face Seal Fitting and sealing gasket to connect to the female swivel 4 VCR or 8 VCR Style Face Seal Fitting NOTE Ti...

Page 4: ...with 5 pin terminal strip and 0 5 and 0 25 OD Tube 0 99 25 0 50 13 3 05 77 3 47 87 0 75 19 0 25 6 3 17 80 1 50 38 Pin 1 Mating connector 0 12 3 05 Pin 1 Terminal strip Model 730 with 0 5 diameter tube...

Page 5: ...0 13 3 24 82 0 75 19 0 25 6 3 0 76 Model 730 with 0 5 diameter tube Model 730 with 0 25 diameter tube Figure 3 Outline drawing of Model 730 with 6 cable and 15 pin D sub and 0 5 and 0 25 OD Tube Pin 1...

Page 6: ...a metal case and it must be in direct contact with the cable braided shield for the entire circumference of the cable A single wire from the shield to the connector case will not be effective 3 The c...

Page 7: ...o an electronically noisy power supply or readout instrument Improved results may be obtained if the transducer is operated in an environment with stable temperature and air flow The lowest recommende...

Page 8: ...model 730 to be 0 001 to 0 001 V Make this adjustment at a pressure at least 1 2 decade below the Model 730 s resolution e g for a 10 Torr FS unit the zero pressure should be less than 5E 5 Torr For...

Page 9: ...e Solution No signal output Incorrect or no supply voltage Ensure power supply is used as specified in Section 3 Readout display short circuit or incorrect impedance Ensure impedance of readout unit i...

Page 10: ...Storage temperature 20 to 85 C Electrical data voltage Excitation Output4 12 to 30 VDC for 0 10 VDC 9 to 30 VDC for 0 5 VDC Current consumption 10 mA max Output load 10 k Load Output impedance 1 ohm...

Page 11: ...ective in materials or workmanship within the warranty period provided that a the product has not been subjected to abuse neglect accident incorrect wiring not our own improper installation or servici...

Page 12: ...Setra Systems Inc 159 Swanson Road Boxborough MA 01719 800 257 3872 www setra com SS730 REV C 1 2019...

Reviews: