SEALED ENERGY SYSTEMS
®
21
User Manual
3.5.
Passive Safety Protection
3.5.1. Overview of Operations
The battery pack is fitted with additional components to protect it
against abusive charge and discharge conditions. These are in
addition to the electronic protection.
3.5.2. Thermal Fuse
A Thermal Fuse is fitted in series with the charge/ discharge path to
protect the battery from over temperature. This device goes open
circuit if the cell case temperature reaches the fuse's temperature
rating of 93°C (+0°C, -5°C). The fuse is non-re-settable rendering
the battery pack non-functional.
3.6.
Mechanical Specifications
3.6.1. Weight
0.650Kg, approximately
3.6.2. Mating Connector
The recommended interconnection mating male connector
is AMP/ TE part no.5787428-1 or 5787421-1
3.6.3. Packing
The batteries are packaged in bulk per current regulations.
3.7. Environmental/Safety Specifications
3.7.1. EMC and Safety
The battery complies with the following:
•
EMC Directive 2004/108/EC
•
Low Voltage Directive 2006/95/EC
•
Battery Recycling Directive 2006/66/EC as amended
•
RoHS Directive 2011/65/EU
The battery has been tested in accordance with the UN Manual of
tests and Criteria part III subsection 38.3 (ST/SG/AC.10/11/Rev.3) -
more commonly known as the UN T1-T8 Transportation tests and
has been found to comply with the stated criteria. [USDOT-E7052]
The battery has the following approvals and the pack will be labeled
according:
•
EN/ IEC 61000-6-3: 2010
•
EN/ IEC 61000-6-1: 2016
•
EN/ IEC 62281: 2016
•
EN/IEC 62133-2:2017
•
CE
•
BIS/ IS16046-2:2018
•
REACH
•
RoHS