4.1.2

 

Standard operating conditions 

The actuator must be used in an environment whose conditions comply with the provisions of Servomech 
S.p.A. The works necessary for obtaining and maintaining that conditions are in charge of the owner and,  
where applicable, are in charge of the end user. 

The actuator must be installed and used indoor only, in dry area with environmental conditions as specified 
below: 

 

Temperature range 

 

 

 

 

+0°C ÷ +40°C 

 

Relative atmospheric humidity   

 

 

5% ÷ 85% 

 

No build up of condensation 

 

THE USE OF THE ACTUATOR IN DIFFERENT CONDITIONS THAN JUST DESCRIBED MUST BE PREVIOUSLY 
DECLARED AND AGREED WITH SERVOMECH, SINCE A SPECIAL EQUIPMENT OF THE PRODUCT MUST 
BE PROVIDED. 

4.1.3

 

Thermal limit 

The actuator duty cycle permissible Fi [%] is the maximum working time expressed in percentage that the 
actuator  can  perform  during  the  reference  time  period  of  10  minutes,  under  rated  load  stated  in  the 
catalogue at ambient temperature 25°C, without risk of internal parts overheating. 

𝑭

𝒊

[%] =

𝑀𝑎𝑥 𝑤𝑜𝑟𝑘𝑖𝑛𝑔 𝑡𝑖𝑚𝑒 𝑜𝑣𝑒𝑟 10 𝑚𝑖𝑛

10 𝑚𝑖𝑛

× 100

 

Linear drive 

Fi [%] 

Acme screw (ATL series) 

30 

Ball screw (BSA series) 

100 

 

For the proper operation of acme screw linear actuators (ATL series) do never exceed the permissible 
duty cycle limit. 

4.2

 

Personnel requirements / Qualifications 

This  manual  must  be  made  available  to  the  personnel  in  charge  of  installation,  start  up  and  use  of  the  
actuator. It is the responsibility of the machine builder:  

 

use personnel with the necessary qualifications for the installation and commissioning of the 
actuator; 

 

periodically check the qualification of the assigned personnel; 

 

check that the personnel in charge are aware of the contents of this manual. 

5

 

STORAGE 

 

Do not store outside.  

 

Storage should be dry and dust-free. 

 

Keep away from any aggressive media. 

 

Protect from UV radiation. 

 

Avoid mechanical vibrations. 

 

Storage temperature:  0 to +50 °C. 

 

Relative atmospheric humidity: max. 95% (no build up of condensation). 

 

To store longer than 6 months, take care of moving the input shafts to prevent damages to 
sealings. 

 

Also check that all unpainted steel parts are adequately protected (oiled and /or greased) to 
prevent oxidation. 

Summary of Contents for ATL 20

Page 1: ...TL 28 ATL 30 ATL 40 BSA 20 BSA 25 BSA 28 BSA 30 BSA 40 Installation operation and maintenance manual Publication 02 20 25 28 30 40 E Rev 01 Date M Y 05 19 Servomech S p A Via M Calari 1 40011 Anzola d...

Page 2: ...y relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not r...

Page 3: ...tions 7 4 1 2 Standard operating conditions 8 4 1 3 Thermal limit 8 4 2 Personnel requirements Qualifications 8 5 STORAGE 8 6 INSTALLATION 9 6 1 Safety warnings 9 6 2 FCE electric stroke limit switche...

Page 4: ...BO ITALY Ph 39 051 6501 711 Fax 39 051 7345 74 Website www servomech com e mail info servomech com 2 2 Description of the product For all the technical characteristics of the product performance featu...

Page 5: ...o of the input drive 3 Stroke length is the stroke length in millimetres achievable by the actuator 4 Linear speed is the linear speed expressed in mm s when the actuator is provided with electric mot...

Page 6: ...g and transporting the linear actuator the push rod must be in retracted position Lift the actuator from the housing and outer tube supporting the motor during transport DO NOT lift the actuator from...

Page 7: ...ith a purely axial applied load They must be subjected to the loading and speed conditions specified in the catalog Modification of parts of the actuator or replacement of components with different an...

Page 8: ...ambient temperature 25 C without risk of internal parts overheating 10 10 100 Linear drive Fi Acme screw ATL series 30 Ball screw BSA series 100 For the proper operation of acme screw linear actuators...

Page 9: ...INSTALLATION AND MAINTENANCE OF THE PRODUCT BEFORE TO PROCEED TO THE ELECTRIC CONNECTION MAKE SURE THE SUPPLY VOLTAGE IS TURNED OFF BEFORE TO TURN ON THE MOTOR MAKE SURE THE ELECTRIC CONNECTIONS ARE...

Page 10: ...d fixes the required RETRACTED ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the stop positions simply release the grub screw on t...

Page 11: ...se refer to the product catalogue or to the check sheet supplied with the actuator When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give th...

Page 12: ...EED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection cla...

Page 13: ...le length 1 3 m Enclosure rating IP 55 The rotary encoder ENC 4 must be connected to the electric control circuit as shown in the following WIRING DIAGRAM 6 5 Rotary encoder GI 2X THE ROTARY ENCODER G...

Page 14: ...bi directional Resolution 100 or 500 pulses per revolution Output PUSH PULL 2 channels A and B phase difference 90 channel ZERO Input voltage 5 24 V DC No load current 100 mA Max commutable current 50...

Page 15: ...ms Figure 6 3 Electric wiring diagrams to power supply a AC 3 phase motor b AC 1 phase motor c DC motor Figure 6 4 Electric wiring diagrams to motor terminal board a AC 3 phase motor b AC 1 phase moto...

Page 16: ...F LOCKING BEFORE TO APPLY ANY AXIAL LOAD ON THE PUSH ROD LOCK THE INPUT SHAFT OR USE THE MOTOR BRAKE ALL MECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSO...

Page 17: ...AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 9 Installation of rod end fitting elements To install a mounting element on the rod end threaded bore BA use a wrench flat on the rod end to counterhold the lo...

Page 18: ...d Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the current actua...

Page 19: ...T LUBRICANT SHOULD BE USED PLEASE CONTACT SERVOMECH BEFORE PROCEED IN CASE OF CUSTOM PRODUCT EXECUTION THE LUBRICANTS COULD BE DIFFERENT FROM THE STANDARD ABOVE TO KNOW THE TYPE OF LUBRICANT PLEASE RE...

Page 20: ...es as shown on Fig 9 2 Grease nipple type DIN71412 M6 Figure 9 2 Linear drive relubrication of ATL BSA 30 40 Apply the grease quantity indicated in Tab 9 1 with several partial quantities Travel over...

Reviews: