If the push rod shifting directions are not compatible: 

A) ACTUATOR WITH THREE-PHASE MOTOR: invert any wire pair (U1 

 V1, or U1 

 W1, or V1 

 W1) into the 

terminal board; 
B) ACTUATOR WITH SINGLE-PHASE MOTOR: change the contact (V1 

 W1); 

C) ACTUATOR WITH DIRECT CURRENT MOTOR: invert contacts of the two motor supply cables. 

In case of brake motor: 

 

the brake is NORMALLY CLOSED (NEGATIVE action). When the power supply is switched off, the brake 
is engaged. The brake opens only when power is supplied; 

 

if the brake is wired directly to the connecting pins of the terminal box, it does not require any power 
supply; 

 

if the brake is wired separately, make sure that the correct voltage is used; 

 

if the brake is equipped with hand release device, make sure that the brake is engaged before starting 
the linear actuator. 

6.8

 

Linear actuator installation 

 

THE  BALL  SCREW  LINEAR  ACTUATOR  (BSA  SERIES)  IS  NOT  SELF-LOCKING.  BEFORE  TO  APPLY  ANY 
AXIAL LOAD ON THE PUSH ROD, LOCK THE INPUT SHAFT OR USE THE MOTOR BRAKE. 

 

ALL MECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT 
DAMAGE TO PERSONS OR PROPERTY. 

 

Check that all plant fixing elements are well machined and cleaned, and that they fit the dimensions of 
the actuators fixing elements they have to be fixed to. 

 

If  the  length  of  the  actuator  have  to  be  changed  (push  rod  more  retracted  or  extended)  during 
installation, power the motor with limited speed and torque values, in order to avoid possible damages 
in case of a mechanical stop is reached. 

 

In case of actuators without anti-rotation device (AR) and/or electrical limit switches device (FCE), it is 
possible to manually screw/unscrew the push rod to change the length of the actuator. 

 

In case of actuators with bellow protection (B): DO NOT TWIST THE BELLOW. 

 

DO NOT SET THE LENGTH OF THE ACTUATOR OVER ITS EXTREME VALUES: 

 

“Lc” = RETRACTED ACTUATOR 

 

“La” = EXTENDED ACTUATOR 

 

Figure 6.6 – “Lc” and “La” dimensions

 

Dimensions “Lc” and “La” are indicated in the technical catalogue of the product and on the check sheet 
supplied with the actuator. 

Summary of Contents for ATL 20

Page 1: ...TL 28 ATL 30 ATL 40 BSA 20 BSA 25 BSA 28 BSA 30 BSA 40 Installation operation and maintenance manual Publication 02 20 25 28 30 40 E Rev 01 Date M Y 05 19 Servomech S p A Via M Calari 1 40011 Anzola d...

Page 2: ...y relieve Servomech S p A from any liability for damage caused to persons and or property Servomech S p A it does not assume direct or indirect responsibility for an improper use of the actuator not r...

Page 3: ...tions 7 4 1 2 Standard operating conditions 8 4 1 3 Thermal limit 8 4 2 Personnel requirements Qualifications 8 5 STORAGE 8 6 INSTALLATION 9 6 1 Safety warnings 9 6 2 FCE electric stroke limit switche...

Page 4: ...BO ITALY Ph 39 051 6501 711 Fax 39 051 7345 74 Website www servomech com e mail info servomech com 2 2 Description of the product For all the technical characteristics of the product performance featu...

Page 5: ...o of the input drive 3 Stroke length is the stroke length in millimetres achievable by the actuator 4 Linear speed is the linear speed expressed in mm s when the actuator is provided with electric mot...

Page 6: ...g and transporting the linear actuator the push rod must be in retracted position Lift the actuator from the housing and outer tube supporting the motor during transport DO NOT lift the actuator from...

Page 7: ...ith a purely axial applied load They must be subjected to the loading and speed conditions specified in the catalog Modification of parts of the actuator or replacement of components with different an...

Page 8: ...ambient temperature 25 C without risk of internal parts overheating 10 10 100 Linear drive Fi Acme screw ATL series 30 Ball screw BSA series 100 For the proper operation of acme screw linear actuators...

Page 9: ...INSTALLATION AND MAINTENANCE OF THE PRODUCT BEFORE TO PROCEED TO THE ELECTRIC CONNECTION MAKE SURE THE SUPPLY VOLTAGE IS TURNED OFF BEFORE TO TURN ON THE MOTOR MAKE SURE THE ELECTRIC CONNECTIONS ARE...

Page 10: ...d fixes the required RETRACTED ACTUATOR stop position Ring 2 activates FC 2 switch and fixes the required EXTENDED ACTUATOR stop position To setup the stop positions simply release the grub screw on t...

Page 11: ...se refer to the product catalogue or to the check sheet supplied with the actuator When using more contact reeds for intermediate positions it shall be considered that the same reed switch can give th...

Page 12: ...EED SWITCHES TECHNICAL FEATURES Contact NC NO Switching output Reed Supply voltage 5 120 V AC DC 1 5 230 V AC DC 2 Voltage drop 0 35 V Continous current 100 mA AC Switching capacity 6 W Protection cla...

Page 13: ...le length 1 3 m Enclosure rating IP 55 The rotary encoder ENC 4 must be connected to the electric control circuit as shown in the following WIRING DIAGRAM 6 5 Rotary encoder GI 2X THE ROTARY ENCODER G...

Page 14: ...bi directional Resolution 100 or 500 pulses per revolution Output PUSH PULL 2 channels A and B phase difference 90 channel ZERO Input voltage 5 24 V DC No load current 100 mA Max commutable current 50...

Page 15: ...ms Figure 6 3 Electric wiring diagrams to power supply a AC 3 phase motor b AC 1 phase motor c DC motor Figure 6 4 Electric wiring diagrams to motor terminal board a AC 3 phase motor b AC 1 phase moto...

Page 16: ...F LOCKING BEFORE TO APPLY ANY AXIAL LOAD ON THE PUSH ROD LOCK THE INPUT SHAFT OR USE THE MOTOR BRAKE ALL MECHANICAL AND ELECTRICAL PROTECTION MUST BE INSTALLED AND ACTIVATED TO PREVENT DAMAGE TO PERSO...

Page 17: ...AXIAL LOAD ARE APPLIED TO THE ACTUATOR 6 9 Installation of rod end fitting elements To install a mounting element on the rod end threaded bore BA use a wrench flat on the rod end to counterhold the lo...

Page 18: ...d Measure the initial length of the actuator then run the actuator GRADUALLY from the control unit in order to reach the plant to its more distant extreme position Check continuously the current actua...

Page 19: ...T LUBRICANT SHOULD BE USED PLEASE CONTACT SERVOMECH BEFORE PROCEED IN CASE OF CUSTOM PRODUCT EXECUTION THE LUBRICANTS COULD BE DIFFERENT FROM THE STANDARD ABOVE TO KNOW THE TYPE OF LUBRICANT PLEASE RE...

Page 20: ...es as shown on Fig 9 2 Grease nipple type DIN71412 M6 Figure 9 2 Linear drive relubrication of ATL BSA 30 40 Apply the grease quantity indicated in Tab 9 1 with several partial quantities Travel over...

Reviews: