6(18)
Supplied without batteries
0560
!
Technical data:
Voltage ............................... 6 volt DC. Batteries 4 x
1.5 volt (AA), or adapter
23-513 (6-9 volt DC 600 mA)
Range ............................... Receiving and
transmission
distance
Transmission frequency ..... 433.92 MHz
Modulation ........................ ASK
Number of channels .......... 256
Detection area ................... at 5 m height 1 x 5 m
at 3 m height 0.6 x 3m
Detection range ................. adjustable up to 8 m
Luminance .......................... adjustable from 5lx to 5000lx
Battery life ......................... approx. 6 months at 10
activations per day
at
20°C
Ambient temperature ......... -20°C…..+45°C
Protection class ................. IP 44
WALK TEST
The sensor 44-063 will operate automatically when the
voltage is connected. If necessary you can conduct a
walk test to ensure that the coverage area is correct.
Before the walk test, METRE is set to “ + “, after which
the walk test can be started.
Procedure for walk test:
1. Position the transmitter so that it covers the
required coverage area.
2. The transmitter should be switched on for 30
seconds before the walk test is started.
3. Ensure that the transmitter and receiver have
the same channel setting.
4. Check whether the transmitter’s LED is
functioning
normally.
5. Get a person outside the coverage area to
move through the coverage area.
6.
The
fi rst time the person activates the
sensor, the LED will light for approx. 2
seconds and transmit a signal to the receiver,
after which the LED goes out. It takes around
5 seconds before the transmitter is ready for
the next activation of the receiver.
7. The detection area is adjusted using METRE
and by turning the sensor.
8. Repeat steps 6 to 8 until the coverage area
meets your requirements.
Note:
Regardless of what setting METRE has, the
widest
range
cannot be regarded as a normal coverage area.
Troubleshooting
When the transmitter does not function satisfactorily,
the following points can be of assistance.
! Reserving the right to make changes !
Problem:
Possible cause:
Proposed solution:
Sensor’s LED does not light.
1. Flat batteries or battery fi tted incorrectly. No
power supply.
1. Replace with correctly fi tted new batteries.
Switch on adapter.
Receiver cannot receive signal.
1. Transmitter and receiver have different
channels set, or too great a distance
between transmitter and receiver.
1. Ensure that the transmitter and receiver
have the same channel setting. Adjust
transmitter and receiver to be within range.