background image

4(18)

GB

Wireless PIR sensor 44-063

Description

The wireless PIR sensor 44-063 is a wireless 
transmitter that combines infrared and wireless 
technology.

The PIR sensor 44-063 can detect people up to 8 m 
away. The sensor is ideal for installation by doorways 
and gateways, on ceilings and walls or placed on a table.

When the receiver receives a signal from the PIR 
44-063 transmitter, the receiver will give a signal that 
welcomes customers or guests. 

 

-  Easy to install by doors, passageways,  

 

 

 

ceilings, walls or placed on a table / shelf.

 

-  Adjust the distance by turning the  

 

 

 

potentiometer marked METRE to the left or  

  

right.

 - 

Wireless

 

-  Can be used in various locations: offi ces,   

 

 

small shops, in the home etc.

 

-  Splash proof for outdoor fi tting.

Channel setting

The transmitter and receiver communicate with each 
other by using the same channel. The PIR sensor 
transmitter is factory set to system channel “1” and 
product channel “9”. You should ensure that both 
channels are the same on transmitter and receiver.
The user can set the receiver to the same channel as 
the transmitter. If the user requires a different channel 
setting, because other systems are set to the same 
channel, the user must change the channels on both 
transmitter and receiver.
Do not use system channel “A” and product channel 
position “1” on sensor 44-063. This combination can 
produce interference from other systems on the market.

Use the following procedure if you want a different 
channel setting for PIR sensor 44-063.
 

1.  Remove the battery cover with a fl at  

 

 

 

screwdriver. Fig. 1

 

2.  Adjust the channel selection with a  

 

 

 

screwdriver. Fig. 2

 

3.  Position batteries with the correct polarity.

 

4.  Replace the battery cover. The cover is the right  

 

 

way round when the screwdriver symbol is  

 

 

located opposite the screwdriver recess. Fig. 1

 

Installation

 

Tips for longer range.

  1.  Install the 44-063 on the ceiling, approx. 2.5 to 
   

5 metres above the fl oor.  

  2.  Before installation, check that the transmitter   
   

and receiver are not too far apart, thus  

 

   

preventing reception of the signal.

 3. Avoid fi tting the PIR transmitter 44-063 close  to
   

aluminium cladding or thick metal, which 

   

reduces transmission distance. Keep it at least 

   

1 metre away.

 4. Avoid fi tting the PIR sensor on very thick walls
   

containing iron, which reduces the  distance to

   the receiver.
  5.  When checking the range, avoid holding the    
   

PIR sensor 44-063 in your hand, as the body   

   

can act as an aerial and produce interference.

  6.  To prevent signal reduction, there should not be
   

several transmitters within a radius of 3 metres.

 7. If fi tted outdoors, avoid turning the sensor head
   

upwards as the sensor can be damaged by 

   

water. Fig. 3

 

Fig. 1 

Fig. 2

Systemchannel

Productchannel

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Fig. 7

Wall mounted or 

positioned on table

Ceiling 

mounted

Mounted above 

door

Ceiling mounted

Mounted by door

Positioned on table

Fig. 8

Choosing the correct location

Detection area  
  1.  The size of the detection area depends on the 
   

height of the sensor above the fl oor. Fig. 4

  2.  Choose a location in which the transmitter and
   

receiver work satisfactorily.

  3.  The PIR sensor 44-063 can be fi tted above a 
   

door. Fig. 5

  4.  On the ceiling. Fig. 6
  5.  At the side of a doorway. Optimal height is 
   

1,2 metres. Fig. 7

  6.  On a table. Fig. 8

Avoid erroneous signals    
The PIR transmitter 44-063 is activated by temperature 
changes that are in movement. The following points 
can remedy unwanted transmitter signals.

  1.  Avoid the object moving towards the sensor,  as
   

this produces the lowest sensitivity.

  2.  Position the sensor so that the person crosses 
   

the segments, which gives the greatest sensitivity.

  3.  Do not position the sensor so that it “looks”    
   

towards a light source.

  4.  Avoid directing the sensor towards bushes that 
   

move in the wind.

  5.  Do not position the sensor close to heat sources, 
   

such as ventilation heat, air conditioning, dryers 

   or lamps.
 6. Avoid refl ective surfaces which can create rapid 
   

changes in temperature.

Receiving and transmission distance

Range outdoor: ............approx. 50 m in open space*.
Range indoor: ...............approx. 25 m in open space*.

Approximately 5-10 m when mounted on a conductive 
surface (e.g. metal/aluminium).  To increase the range 
the Wireless Signal Extender 23-085 can be used. The 
Wireless Signal Extender 23-085 can double the range 
and are mounted in a straight line.

*when using the adapter or batteries (4 x AA 1,5V 
alkaline).

Summary of Contents for 44-063

Page 1: ...egge kanaler er ens p sender og modtager Brugeren kan selv indstille modtageren til at have samme kanal som senderen nsker brugeren en anden kanalindstilling fordi andre systemer er indstillet p samme...

Page 2: ...10 aktiveringer pr dag ved 20 C N r batterierne bliver afladt vil LED blive svag og r kkevidde p sender blive kortere Nye batterier is ttes som beskrevet tidligere Sensor kan tilsluttes adapter i sted...

Page 3: ...enderens LED fungerer normalt 5 Lad en person udenfor d kningsomr de bev ge sig p tv rs af d kningsomr det 6 F rste gang personen aktiverer sensoren vil LED lyse i ca 2 sek og sende et signal til modt...

Page 4: ...r 44 063 close to aluminium cladding or thick metal which reduces transmission distance Keep it at least 1 metre away 4 Avoid fitting the PIR sensor on very thick walls containing iron which reduces t...

Page 5: ...r Fig 1 2 Insert the adapter DC plug into the sensor socket Fig 10 3 Cut a hole in the cover of the adapter cable Fig 11 4 Refit the battery cover and ensure that the cable fits through the opening Fi...

Page 6: ...ransmitter s LED is functioning normally 5 Get a person outside the coverage area to move through the coverage area 6 The first time the person activates the sensor the LED will light for approx 2 sec...

Page 7: ...Den PIR Sender 44 063 nicht zu nahe an Aluminiumverkleidungen bzw starken Metallteilen montieren die die Reichweite verringern Auf einen Abstand von mindestens 1 Meter achten 4 Den PIR Sensor nicht an...

Page 8: ...ehmen Abb 1 2 Gleichspannungsstecker in die Sensor buchse stecken Abb 10 3 Eine ffnung in die Abdeckung des Adapter kabels schneiden Abb 11 4 Batteriefachdeckel wieder aufsetzen und darauf achten dass...

Page 9: ...n au erhalb durch den Erfassungsbereich gehen lassen 6 Bei der ersten Sensoraktivierung durch die Person leuchtet die LED f r ca 2 Sekunden und der Sender sendet ein Signal an den Empf nger Anschlie e...

Page 10: ...Pose au plafond Pose au dessus d une porte Pose au plafond Pose c t d une porte Pose sur une table Fig 8 Installation Astuces pour une port e optimale 1 Poser le d tecteur 44 063 au plafond environ 2...

Page 11: ...14 Fig 9 Fig 10 Fig 17 Fig 18 P U S H T O R E L E A S E S E N S O R AB S 0 90 o 15 30 45 60 0 0 90 o o Fig 19 Appuyer sur la languette Degr s Point d alignement Fig 21 Evidement pour le c ble Trou de...

Page 12: ...une personne qui tait plac e en dehors 6 La premi re fois que la personne active le d tecteur le t moin lumineux s allume pendant env 2 secondes un signal est transmis au r cepteur puis le t moin lumi...

Page 13: ...063 i tak p cirka 2 5 till 5 meters h jd ver golvet 2 Kontrollera f re installation att avst ndet mellan s ndare och mottagare inte r s stort att tillf rlitlig funktion ventyras 3 Montera inte PIR det...

Page 14: ...i skruv Fig 13 Fig 14 Fig 9 Fig 10 Fig 17 Fig 18 P U S H T O R E L E A S E S E N S O R AB S 0 90 o 15 30 45 60 0 0 90 o o Fig 19 Utl sartapp Grader Uppriktningspunkt Fig 20 Fig 21 Upph ng ningsh l H l...

Page 15: ...nf r t ckningsomr det r ra sig tv rs ver t ckningsomr det 6 F rsta g ngen personen aktiverar detektorn lyser lysdioden i cirka 2 sekunder och s nder en signal till mottagaren varefter lysdioden sl cks...

Page 16: ...meter hoogte van de vloer 2 Controleer v r de montage of de afstand tussen de zender en ontvanger niet groter is dan voor een goede ontvangst van het signaal is vereist 3 Monteer de PIR zender 44 063...

Page 17: ...platte schroevendraaier Fig 1 2 Steek de DC stekker van de adapter in de contrastekker van de sensor Fig 10 3 Knip een gat in het klepje voor de kabel van de adapter Fig 11 4 Monteer het batterijklep...

Page 18: ...ormaal functioneert 5 Laat iemand van buiten het dekkingsgebied dwars door het dekkingsgebied lopen 6 De eerste keer dat deze persoon de sensor activeert zal de LED ca 2 sec oplichten en een signaal s...