ServerNet LS24I User Manual Download Page 37

LS24I/M

 

  

               

37  

 

LS24I/M User guide  

 

Copyright ServerNet S.r.l. 2015-2016, All Rights Reserved

 

6.4.

 

Battery charging 

 

By design LS24I/M works along with other devices, LS24I
be turned on when it has USB B (on power transition) or 
source active.  

LS24I/M  internal  battery  is  intended  only  as  temporary  power  backup  to 
support  device  in  case  of  temporary  power  source  failure
inadequate or insufficient external power level.  

By  design,  the  LS24I/M  is  maintaining  the  battery  fully 
cannot be changed by any option including powering of the device. 

For LS24I/M battery charging status, refer to battery charging orange LED
on the front panel.  

If  battery  charging  LED  is  ON,  device  is  charging  its  battery;  if  it  is  OFF, 
device  is  not  charging  its  battery.  No  assumption  about  the  battery  level 
should be made by the user without accessing LS24I/M web interface.

See the previous chapter 1.6.1 “LED indicators” for more details on 
charging LED information. 

IMPORTANT 
If your device was inactive or configured and never used for a long 
time  (3  months  or  more)  or  its  internal  battery  is  completely 
discharged,  you  need  to  restore  battery  charge  condition
following steps:  

 

Put the device in charge using a wall power adapter. 

 

Since  device  switches  on  automatically  if  powered,  you  must 
press  and  hold  the  ON/OFF  button  in  order  to  force  device 
switch off.  

 

Wait until the battery LED switches off (battery fully charged). 

You  can  now  use  your  device:  this  procedure  will  avoid  the 
problems  that  might  occur  with  internal  battery  completely 
discharged condition. 

 

 

 

               

 

     Apr, 2016 

 

with other devices, LS24I/M is designed to 

or 7-30V DC power 

LS24I/M  internal  battery  is  intended  only  as  temporary  power  backup  to 

device  in  case  of  temporary  power  source  failure  or  temporary 

  charged  and  this 

cannot be changed by any option including powering of the device.  

r to battery charging orange LED 

is  ON,  device  is  charging  its  battery;  if  it  is  OFF, 

device  is  not  charging  its  battery.  No  assumption  about  the  battery  level 
should be made by the user without accessing LS24I/M web interface. 

indicators” for more details on battery 

your device was inactive or configured and never used for a long 

battery  is  completely 

you  need  to  restore  battery  charge  condition  with  the 

ut the device in charge using a wall power adapter.  

omatically  if  powered,  you  must 

press  and  hold  the  ON/OFF  button  in  order  to  force  device 

switches off (battery fully charged).  

You  can  now  use  your  device:  this  procedure  will  avoid  the 

th  internal  battery  completely 

Summary of Contents for LS24I

Page 1: ...LS24I M Device User s Guide...

Page 2: ...Rights Reserved Identifier LS24 Document Version 04 04 Effective Date Apr Document Catalog Number LS24 Author Michele De Monte Technical review Vedran Jukic Approval Angelo Pingue LS24I M 2 LS24I M 04...

Page 3: ...abelling 1 6 Controls and Indicators 1 6 1 LED Indicators 1 6 2 Audio indicators 1 6 3 Symbols 1 7 ServerNet s Responsibilities 2 LS24I M features 2 1 LS24I M main features 2 2 LS24I M internal access...

Page 4: ...r connector only for LS24I 6 4 Battery charging 6 5 Turning on LS24M OS loading and status LED options 7 Using LS24I M 8 Accessing the LS24I M 9 LS24I M OS use and configuration 10 System recovery 11...

Page 5: ...ssification 04 02 Nov 02 2015 Update with UL request for warnings for IT Network devices 04 03 Nov 18 2015 User manual download link added minor language changes 04 04 Apr 06 2016 Improved in Chapters...

Page 6: ...ned device version IMPORTANT Medical grade routing and computing device models LS24I and LS24M are MEDICAL GENERAL MEDICAL EQUIPMENT AS TO ELECTRICAL SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDAN...

Page 7: ...uide link card for online user manual download Some other accessories can be assembled inside of the LS24I M part of the package to complete its wide connectivity set Refer to the product number P N f...

Page 8: ...SB A to B cable for device power supply 5V Friwo GPP USB 5V 1500 mA USB power supply UL medical grade certified part number 1895382 optional to be ordered separately Friwo FW7721M GPP USB primary adap...

Page 9: ...VE DEVICE COVER Refer servicing to qualified and ServerNet authorized personnel only Final user personnel must refer to third part configuration to know how to operate with the device during the speci...

Page 10: ...riwo USB power adapter referred also as Friwo USB power adapter part number 1895382 or Friwo GPP USB or Friwo FW7721M 1 3 Intended Use The LS24I and LS24M are general routing and computing device for...

Page 11: ...ry was completely discharged a few seconds to a few minutes may occur to catch a minimum level battery operation charge LS24I M is classified as Classified device by UL when used together with Friwo G...

Page 12: ...with UL 60601 1 3 1 Edition requirements If supplied with the 7 30V power source LS24I is not considered by UL a Classified device Take care to evaluate in advance your application in accordance with...

Page 13: ...150 kHz 30 MHz 6 1 1 2 Radiated disturbance 30 MHz 1 GHz Immunity 6 2 2 Electrostatic discharge ESD 6 2 3 Radiated RF electromagnetic fields 6 2 4 Electrical fast transients and bursts 6 2 5 Surges 6...

Page 14: ...for connection to an existing wireless LAN Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received...

Page 15: ...e LS24I M you have to follow your organization s recommendations on placement of wireless devices Do not use the LS24I M with 3G UMTS radio module equipment without requesting permission from your Res...

Page 16: ...er Model P N indicates device product model related to customer features OS Release indicates installed release for the OS ASSY week indicates assembly week YYYY WW S N indicates serial number MAC s f...

Page 17: ...customer features OS Release indicates installed release for the OS ASSY week indicates assembly week YYYY WW S N indicates serial number MAC s for LAN1 and LAN2 3G UMTS FCC ID and IC Label symbols F...

Page 18: ...ted to customer features OS Release indicates installed release for the OS ASSY week indicates assembly week YYYY WW S N indicates serial number MAC s for LAN1 LAN2 and WiFi WiFi FCC ID and IC Label s...

Page 19: ...serial number MAC s for LAN1 and LAN2 3G UMTS FCC ID and IC Label symbols For Configuration support refer to Configuration Distributor documentation Please see Controls and Indicators to know the symb...

Page 20: ...I double power Batch reference 2 capital letters Progressive number 4 digits L D CPU identification label for batch tracking Dimensions 15x5 mm Material polyester Includes Board type 1Gb standard mem...

Page 21: ...letely mapped by the third part Configuration Refer to third part Configuration specific documentation from the Configuration Distributor to know COM indicator mapped running mode Indicator Device sta...

Page 22: ...LED A complete battery status and charge level is available trough the web interface 1 6 2 Audio indicators LS24I M includes an audio buzzer Sound indicator is not used in any part of OS boot and run...

Page 23: ...ser Manual Refer the user to the proper instruction manual UL Certification mark for US and Canada Class 1 insulation device ON OFF button with complete device power off Press and hold for 3 seconds L...

Page 24: ...le for the LS24I M safety reliability and performance while the following is met Readjustments or repairs or maintenance are carried out by authorized and qualified personnel The equipment is used in...

Page 25: ...mA USB type B pwr connector 7 30V 5W DC power supply connector only for LS24I Battery Lithium Battery 1750 mAh Medical Grade Operating 20 C 60 C Op with battery in hospital 10 C 40 C hospital minimum...

Page 26: ...n module GSM GPRS 3G Module with GPS replaces WiFi Module 2 x dip pentaband GSM GPRS UMTS terminal antenna Features can be modified every time by ServerNet depending on component supply conditions and...

Page 27: ...ctors 3 2 LS24M front connectors On Off button Eth Lan1 RJ45 Eth Lan2 RJ45 USB A 2 0 USB B PWR Status LED multicolor Battery charging LED On Off button Eth Lan1 RJ45 Eth Lan2 RJ45 USB A 2 0 USB B PWR...

Page 28: ...2015 2016 All Rights Reserved 3 3 LS24I M rear connectors 3 4 LS24I M front rear top view Serial1 RJ45 Serial2 RJ45 Serial3 RJ45 Serial4 RJ45 WiFi SMA WiFi BT COM LED multi color Protective Ground M3...

Page 29: ...mounting in vertical orientation for example wall mounting a standard bracket is provided ServerNet suggests mounting the bracket of your device with a vertical orientation in order to improve device...

Page 30: ...Since LS24I M has more or less square very small dimensions also mounted also horizontally In this case it is strictly recommended to use a cable tie to avoid device unlocking LS24I M 30 more or less...

Page 31: ...ie In this case to remove the device it should be necessary to unlock the removable tie or to cut the zip tie before extracting the device from the bracket Beaded and zip cable ties are not supplied w...

Page 32: ...e mounting bracket is not needed Medical grade velcro is not supplied with LS24I M since length and dimension are related to specific customer implementation IMPORTANT Choose features of your componen...

Page 33: ...lowing session Using LS24I M in chapter 0 No video signal can be received listened directly from this kind of device Only Status LED is designed to give feedbacks while in running mode Since LS24I M g...

Page 34: ...discharge when LS24I M is re external power sources it boots up automatically instructions in chapter 6 4 Battery charging for device internal battery charge when it is completely discharged For LS24...

Page 35: ...switches off Battery is eventually in charge LS24M ON Internal battery Pressing and holding the ON OFF button you remove completely device power source Device switches off LS24M OFF USB B pwr external...

Page 36: ...up OS and goes in running mode Until the 7 30V DC connector is plugged giving power to the device will stay on If the external 7 30V power source desists LS24I uses the battery until it has adequate l...

Page 37: ...Put the device in charge using a wall power adapter Since device switches on automatically if powered you must press and hold the ON OFF button in order to force device switch off Wait until the batt...

Page 38: ...wer supply mode is checked the ON OFF status LED orange indicating device OS loading process When loading is completed after 5 7 seconds and device is mode status LED is fading flashing blue See the p...

Page 39: ...es of your LS24I M device refer to the Device Operating System User s Guide 10 System recovery To explain how to recovery your LS24I M device refer to the Operating System User s Guide or refer to htt...

Page 40: ...3 Disposal of the Product Obsolete or inoperative LS24I M units must be disposed of properly as electronic waste in accordance with all current disposal regulations of your country province state coun...

Page 41: ...LS24I M User guide Copyright ServerNet S r l 2015 2016 All Rights Reserved ServerNet S r l Localit Padriciano 99 34149 Trieste Italy LS24I M User guide Copyright ServerNet S r l 2015 All Rights Reserv...

Reviews: