Serpent SPLICE-500 MKII Manual Download Page 2

SPLICE™ MKII MANUAL V.1.1

 

2

 

 

www.serpentaudio.com

 

1. DESCRIPTION / OVERVIEW:

 

The SPLICE-500™ MKII is a single channel FET based compressor, and can be 
used for mono applications, or can be paired with a second SPLICE-500™ MKII for 
stereo applications.  The SPLICE-500™ MKII’s unique circuitry mode switching 
allows the user to configure the input & output audio path circuitry between classic 
Blackface and Blue Stripe modes, or mix and match the two to create completely 
new sounds, unique to the SPLICE-500™ MKII. 

2. SPECIFICATIONS: 

Maximum Current Consumption: 

175mA* @ +/-16V

 

Input: 

Constant 600R Input Attenuator, Floating Transformer Balanced 

Output:

 Floating Transformer Balanced 

Output (With Mix Enabled):

 <100 Ohm Output Impedance, Transformer-like 

Floating Output, Electronically Balanced (Accepts Balanced or Unbalanced Signals)

 

External Send:

 <100 Ohm Output Impedance, Transformer-like Floating Output, 

Electronically Balanced (XLR) (Accepts Balanced or Unbalanced Signals)

 

External Return:

 22KHz Input Impedance, Electronically Balanced (XLR), (Accepts 

Balanced or Unbalanced Signals) 

Maximum Input Level:

 +30dbu with compression engaged and Input level knob set 

to max (fully clockwise) 

Maximum Output Level:

 +24dbu 

Output Load:

 150 Ohm minimal 

Gain:

 45db (+/-1dbu) with compression disabled (Ratio set to “BP”)

 

Gain Reduction Element: 

FET 

THD+N:

 (20Hz-20KHz) Typically 0.5%

 

Signal-To-Noise Ratio:

 >80dbu 

*Before installation, ensure that the SPLICE-500™ MKII’s power requirements do 
not exceed your 500 series rack’s power supply rating. 

Summary of Contents for SPLICE-500 MKII

Page 1: ... and built in the USA Through our dedication to advanced engineering high quality components and research from industry pros you can expect years of reliability and great customer service THANK YOU TABLE OF CONTENTS DESCRIPTION OVERVIEW 2 SPECIFICATIONS 2 INSTALLATION OPERATION 3 FRONT PANEL CONTROLS 3 MAINTENANCE AND CLEANING 8 WARRANTY 8 ...

Page 2: ...Transformer Balanced Output With Mix Enabled 100 Ohm Output Impedance Transformer like Floating Output Electronically Balanced Accepts Balanced or Unbalanced Signals External Send 100 Ohm Output Impedance Transformer like Floating Output Electronically Balanced XLR Accepts Balanced or Unbalanced Signals External Return 22KHz Input Impedance Electronically Balanced XLR Accepts Balanced or Unbalance...

Page 3: ...minimum of 5 minutes after power down before handling It is important to ensure adequate ventilation of the module while in operation The SPLICE 500 MKII should never be placed adjacent to another heat source or high power 500 module While it is not required it is recommended to leave a blank slot space to the right of the module in your 500 series rack to ensure adequate cooling and ventilation O...

Page 4: ...pression that takes place after the input signal has crossed the threshold point The higher the ratio the more the signal that crosses the threshold will be compressed Ratios of 10 1 or higher are generally considered limiting rather than compression The SPLICE 500 MKII has stepped ratio times of 2 1 4 1 8 1 12 1 20 1 The Ratio has a control at its fully counterclockwise position labeled 1 which a...

Page 5: ...in reduction At this point you may have too much of a good thing Simply turn the Wet signal down until you have blended in the desired amount of Dry signal Listen for overall amount of dynamics and control You should be able to dial in quickly and easily just the right amount for detail and density squeeze and sustain Meter The LED meter indicates gain reduction When no gain reduction is occurring...

Page 6: ...unique to the SPLICE MKII i e Blue Stripe Input circuit Blackface Output circuit or Blackface Input circuit Blue Stripe Output circuit Note The default mode when unit is powered on is Blackface Note The switching recovery time for Input mode switching is approximately 2 seconds when the release knob time is set to its fastest setting fully clockwise Long release time settings will increase the Inp...

Page 7: ...ing the Link toggle switch on both units to the up position 600R Loading Jumper The SPLICE 500 MKII allows for easily terminating the output signal with a 600R load for optimal signal transfer for use with both vintage and modern gear Note When connecting the SPLICE 500 MKII s output to vintage 600R equipment typically known as bridging the loading jumper should be disabled connected to pins 2 3 W...

Page 8: ...g improper storage conditions power surges lightening or other natural disasters Warranty does not cover wear and tear items such as pots and switches or cosmetic wear Shipping and transport damages are not covered under warranty In the event of required maintenance within the warranty period unit should be returned to Serpent Audio or authorized repair facility Inbound freight charges are the res...

Reviews: