BlueSnap
Commands Version 4.81SIO, 1/20/2016 Page 25 of
27
Cedar Park, TX, USA
•
(512) 994-3630
•
www.serialio.com
10
BlueSnap Configuration Switches
1- FACTORY DEFAULTS-
Set this switch ON, power up unit, and toggle the switch from ON to OFF 3 times to return the unit
to factory settings.
2-AUTO DISCOVER MODE
– In Slave mode, sets a special class of device which is used by a remote Master to auto connect.
IF Switch 3 also SET, the device performs a search, stores, and connects to a remote slave which has this switch 2 set .
3- AUTO MASTER MODE-
BlueSnap acts as master, auto-connect to a stored remote address. First set the BT address of the
device to connect to using the SR command. or, have BlueSnap auto discover and connect by via Switch 3 AND Switch 2.
4- DEFAULT BAUD RATE
- OFF = 115K (factory setting), ON = 9600. Overridden by software configuration.
Instant Cable Replacement Example
MASTER
SLAVE
1.
Set switches as shown above.
2.
Power up both devices
3.
Master finds and store slave address, and auto connects.
4. Set Switch 2 on both Master and Slave back to OFF.
BOTTOM SIDE
4- Default baud(9600/ 115k)
3- AUTO MASTER
2 - AUTO DISCOVER
1 – FACTORY DEFAULTS
ON - OFF
BOTTOM SIDE
4- Default baud(9600/ 115k)
3- AUTO MASTER
2 - AUTO DISCOVER
1 – FACTORY DEFAULTS
ON - OFF
BOTTOM SIDE
4- Default baud(9600/ 115k)
3- AUTO MASTER
2 - AUTO DISCOVER
1 – FACTORY DEFAULTS
ON - OFF