6
Replacement Procedures
Service Manual
Serene HB80/110
2
Replacement Procedures
Cabinet
Interior Light
The chiller is lit by fluorescent tube lighting or by LED strip lighting. See
the table below for lighting details.
To replace a fluorescent lamp
To replace an LED strip
Model:
HB80
HB110
Fluorescent tube
lighting
1 x 5 Watt / 865 OSRAM DULUX S fluorescent tube
(switched)
LED strip lighting
4 x vertical LED lights
(total 4W)
n.a.
1. Isolate the chiller from the power supply.
2. Remove the light cover by carefully bending out the side clips.
3. Pull the fluorescent
lamp out of the lamp
holder.
4. Replace with a maximum 5 Watt fluorescent lamp.
5. Carefully align the
side clips on the light
cover and fit back
into place.
6. Reconnect the cabinet to the power supply.
1. Isolate the chiller from the power supply.
2. Unclip the light cover
from the inside of the
door frame.
Continued over page
Fluorescent lamp
Lamp holder
Light cover