Sercomm SW-DWS02N Installation Manual Download Page 3

 

 

4.

 

SW-DWS02N can be included and operated in any Z-Wave network with other Z-Wave certified devices 
from other manufacturers and/or other applications. All non-battery operated nodes within the network will 
act as repeaters regardless of vendor to increase reliability of the network. 
 

5.

 

Association  

Support grouping identifier = 1  
Support one group with 5 nodes. 
All triggering report and low voltage report will be sent to the associated nodes. 

   

6.

 

Awake mode 

It will be triggering after opening bottom cover. SW-DWS02N will send “Wake Up Notification” after 10 
seconds. If SW-DWS02N received “Wake Up No More Information” command then will go off or it will 
wait 10 seconds then go off. It will proceed all the commands after sending the “Wake Up Notification”. 
 

7.

 

Auto Wake Up 

Use “Wake up” command to set up the awaking time and send the wake up notification to controller. 
User can use command to change the auto wake up from 1 minute to 24 hours, interval increment is 1 
minute. Factory default is 120 minutes. 

 
 
 

• 

COMMAND_CLASS_ZWAVEPLUS_INFO 

• 

COMMAND_CLASS_VERSION 

• 

COMMAND_CLASS_MANUFACTURER_SPECIFIC 

• 

COMMAND_CLASS_DEVICE_RESET_LOCALLY 

• 

COMMAND_CLASS_POWERLEVEL 

• 

COMMAND_CLASS_BATTERY 

• 

COMMAND_CLASS_NOTIFICATION 

• 

COMMAND_CLASS_ASSOCIATION 

• 

COMMAND_CLASS_ASSOCIATION_GRP_INFO 

• 

COMMAND_CLASS_BASIC 

• 

COMMAND_CLASS_WAKE_UP 

• 

COMMAND_CLASS_FIRMWARE_UPDATE_MD 

 
 
 
 
 
 
 
 
 
 
 
 
 

Z-Wave Command Classes 

Figure 6 

Alignment Mark

 

 

Reviews: