Sercomm Genesis OC3505D Quick Installation Manual Download Page 6

 

6.

 

Manually adjust the Genesis CPE vertically and horizontally until you have obtained the 
best RSRP (-80) (this value is not guaranteed depending on installation location) and SINR 
(30 or higher) values. These values will refresh every 2 seconds.  

 

 

If  SINR < 5 

 

Double check the eNode direction. 

 

Adjust the Genesis CPE so SINR will raise with minimum RSRP drop. 

 

Try another location. 

If  RSRP < -120 

 

Manually adjust the Genesis CPE to obtain a better RSRP value. 

 

Try another location. 

7.

 

Restore the computer IP to DHCP mode in order to access the Internet again. 

8.

 

 Follow Step 2 &3 to access Genesis FWA CPE.. 

Step 6

Final Check 

1.

 

Tighten the M6 hex bolts on the mounting bracket. 

2.

 

Install the Genesis CPE side door to cover all I/O ports. (PH1 screwdriver required) 

 

 

Summary of Contents for Genesis OC3505D

Page 1: ...CPE Quick Installation Guide 1 Overview This product is an outdoor FWA CPE designed to support band 48 2 Package Contents 1 Genesis FWA CPE 2 Mounting Kit 1 Mounting Bracelet 2 Holder 4 Nut 4 M6 Hex...

Page 2: ...to default values When pressed and held over 5 sec onds the settings of the device will be set to the default values Console Port This port is used for root access to the device through a serial in t...

Page 3: ...onnecting the Ethernet cable to the PoE port of the device Step 2 Insert the micro SIM card 1 Detach the SIM card cover from the device 2 Insert the micro SIM card not included into the card slot Note...

Page 4: ...8mm wrench driver required 3 Keep the M6 hex bolts on the mounting bracket loosen for adjusting the direction of the Genesis CPE later 4 Use a mobile phone compass app or Google maps to determine the...

Page 5: ...et cable to the IN port of the PoE injector and the other end to a computer 2 Access Genesis FWA CPE Web UI on the computer via the following URL https 10 10 2 254 Username Password admin admin 3 The...

Page 6: ...ode direction Adjust the Genesis CPE so SINR will raise with minimum RSRP drop Try another location If RSRP 120 Manually adjust the Genesis CPE to obtain a better RSRP value Try another location 7 Res...

Page 7: ...ification Item Specification Dimension 307mm x 307mm x 77 8mm Height x Width x Depth Power PoE Power Over Ethernet Operation Temperature 40 C 55 C Storage Temperature 40 C 70 C LAN Port 1 10 100 1000B...

Page 8: ...particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to...