Data Pro
P/N 10029355 Rev AE
Operation Manual
Page 32 of 92
NOTE:
The Data Pro will scan the configured range for FIC interfaces. Default scan
‘Start –
End’ address range is 1 through 8. If the FIC interface is outside this range, the FIC
interface will not be detected.
8.5.1
FIC Status
The FIC communicates with the attached GRC gauges using FSK technology and communicates with
the Data Pro application using Modbus protocol.
Information displayed on the FIC Status tab (
1. Total gauge channels communicating
2. Restart Gauge Interface (see Section 8.5.2)
3. Firmware version
4. Operating time since the last power up
5. Line and COM voltage setting
6. Communication Signal level (minimum/ average /maximum)
7. Firmware Update
8. Communication packet count
9. Total gauge channels detected
10. Save and Clear gauge option (see Section 8.5.4)
Figure 28
– FIC Status Screen
10
9
8
7
6
5
4
3
2
1