background image

DA

L  

19

65

Pag. 2/5

1

230V~

3x1,5 

mm²

4  x 0,5 

mm²

2  x 0,5 

mm²

4  x 0,5 

mm²

4  x 1,5 

mm²

4  x 1,5 

mm²

2  x 0,5 

mm²

3 x 0,5 

mm²

RG58 + 2 X 0,75 

mm²

1

2

4

5

5

6

3

M

T

/2

A

  

 E

+

C

F

/2

A

4

M/10 electric key

5

Pair of P/10 photocells

6

RZ/20 F Flashing light with antenna 

1

MT/2A

2

CR/41 electronic control unit with built-in receiver

3

OG/62 2-channel minitransmitter 

Geared  motor 

STANDARD INSTALLATION

Advice for wiring up in non-specialised environments.

1. Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3mm between the contacts. Or, 

alternatively, use a 10A thermal magnetic circuit breaker.

2. Always make connections, of any type, with the system disconnected from the power supply, i.e. with the main switch 

set to OFF (symbol “0”). The control unit, in particular, must never be connected to the power supply either during the 
wiring up, or when fitting any expansion boards.

3. The following cables must be used for installation of the system: 

2

2

- for the control unit, motor and electric lock power supplies: 1.5mm  section for lengths of up to 19m, 2.5mm  section 

for lengths of up to 31m,

2

2

- for the flashing light: 0.75mm  section for lengths of up to 3m, 1.5mm  section for lengths of up to 19m,
- for the low voltage and current lines, (e.g. for the photocells, control buttons, electromechanical key, sensitive 

2

2

edges and other safety devices: 0.5mm  section for lengths of up to 50m, 0.75mm  section for lengths of up to 100m.

4. Wire up the earth connection in compliance with legal provisions.

EMERGENCY OR MANUAL MANOEUVRE

You have to do the emergency or manual manoeuvre or during the installation, or only 
if the automation does not work properly or if there is not power supply.

·

Cut off the power supply.

·

Put the supplied key “CHS” in the hole “V” and turn the left leaf clockwise or the 

right leaf anticlockwise, to free the gear, so open the gate manually.

·

In order to re-establish the normal functioning of the automation, you have to put 

the leaf in the starting position (it starts automatically).

·

Place the key “CHS” in a safety place known exclusively from the people intended 

for the use of the automation. 

·

Switch on the power supply, pay attention that there's nobody where the gate is 

moving.

Reviews: