![Sequentix P3 SEQUENCER Operation Manual Download Page 142](http://html1.mh-extra.com/html/sequentix/p3-sequencer/p3-sequencer_operation-manual_1245593142.webp)
Sequentix Music Systems
P3 Sequencer User Manual
Page 142
Each
accumulator
has a
reverse switch
.
These are just another on/off value, like the gate, tie or skip values in a pattern.
When an accumulator is cleared its
reverse switch
is also turned
off
, so they normally have no effect.
But if you configure the
limit behaviour
to either “
rvtz”
or “
rvbp”
, when the accumulator reaches its
limit, the
reverse switch
is
inverted
– that is, if the switch is off, it is turned on; or if it is on, it is turned
off.
The effect of turning
on
the
reverse switch
is that any
relative offset
to the accumulator is
subtracted
from the accumulator value, rather than
added
to it. - the effect of a
relative offset
is
reversed
.
Let’s look at what this does to the example pattern.
You have a four note arpeggio, with “offset note rel” assigned to aux A.
Aux A is adding
12
to the
note accumulator
every time
step 1
is passed.
With the
default
accumulator config, the
note accumulator
rises to
36
(3 octaves up), then is
reset to
zero
.
To change the
limit behaviour
, press the soft-key below it on the display –
F1
.
Each press of
F1
advances to the next option, so if you press F1 twice, it will step from
rtz
to
clip
to
rvtz
.
Once “
rvtz
” is shown in the display, press the “
OK
” soft-key,
F3
.
This table shows what happens now:
Step
1
2 3
4 1 2 3
4 1
2 3
4
1
2 3
4
Stored Note
C5 E5 G5 C6 C5 E5 G5 C6 C5 E5 G5 C6
C5
E5 G5 C6
aux A
12 off off off 12 off off off 12 off off off
12
off off off
Note Acc
12 12 12 12 24 24 24 24 36 36 36 36
24
24 24 24
Reverse sw.
off off off off off off off off off off off off
on
on on on
Played Note
C6 E6 G6 C7 C7 E7 G7 C8 C8 E8 G8 C9
C7
E7 G7 C8
When the offset event on the step shown in
bold
attempts to push the accumulator beyond its limit, the
reverse switch is turned on, and the offset value is subtracted from the accumulator.
The notes start shifting downward by an octave each time.
This will continue until the accumulator value reaches
zero
.
With the
limit behaviour
set to
reverse to zero,
when an offset event attempts to move the
accumulator below zero, the
reverse switch
is turned
off
, and the accumulator starts to rise again.
Summary of Contents for P3 SEQUENCER
Page 1: ...SEQUENTIX MUSIC SYSTEMS Ltd P3 SEQUENCER OPERATION MANUAL V3 1 006 2006...
Page 2: ......
Page 152: ...Sequentix Music Systems P3 Sequencer User Manual Page 152...
Page 154: ...Sequentix Music Systems P3 Sequencer User Manual Page 154...
Page 156: ...Sequentix Music Systems P3 Sequencer User Manual Page 156...